Evidence map›Paper›PMID 40744949›Full record

ArticleScientific reports2025

AI-assisted intraoperative navigation for safe right liver mobilization in pure laparoscopic donor hepatectomy: an experimental multi-institutional validation study.

Namkee Oh, Manuel Lim, Bogeun Kim, Jongmin Shin, Seonmin Park, Jinsoo Rhu, Jongman Kim, Chan Woo Cho, Gyu-Seong Choi

Abstract readMulticenter StudyValidation Study
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Namkee Oh *Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.
Manuel Lim *Department of Surgery, Myongji Hospital, Goyang, Korea.
Bogeun KimResearch Institution for Future Medicine, Samsung Medical Center, Seoul, Korea.
Jongmin ShinResearch Institution for Future Medicine, Samsung Medical Center, Seoul, Korea.
Seonmin ParkResearch Institution for Future Medicine, Samsung Medical Center, Seoul, Korea.
Jinsoo RhuDepartment of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.
Jongman KimDepartment of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.
Chan Woo ChoDepartment of Surgery, Yeungnam University Medical Center, Deagu, Korea. cwcho1978@naver.com.
Gyu-Seong ChoiDepartment of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea. med9370@gmail.com.

Funding

Korean government (MSIT) RS-2024-00392495Samsung Medical Center, Sungkyunkwan University SMX 1230771
6 · The paper itself

Abstract

Minimally invasive liver surgery (MILS) offers significant benefits but faces limited adoption due to its steep learning curve. This study explores the potential of artificial intelligence (AI) in assisting the performance of major MILS by providing intraoperative navigation through real-time segmentation of the safe plane for dissection. We developed and validated a deep learning model for segmenting vascular structures and the avascular plane during pure laparoscopic donor right hepatectomy (PLDRH). The study utilized 48 PLDRH videos from three institutions, with 40 videos used for five-fold cross-validation and 8 for external validation. The U-Net architecture with Mix Transformer encoder was employed for segmentation. Model performance was assessed using Dice similarity coefficient (DSC), precision, recall, and specificity. In internal validation, the model achieved mean DSC of 0.687 (SD 0.21) for vascular structures and 0.659 (SD 0.19) for the avascular plane. External validation showed comparable performance with DSC of 0.649 (SD 0.24) for vascular structures and 0.646 (SD 0.19) for the avascular plane. Visual assessment demonstrated accurate segmentation across different stages of right liver mobilization, despite lower quantitative metrics for vascular structures. This multicenter external validation study demonstrates the feasibility of AI-assisted intraoperative navigation for safe right liver mobilization in MILS. While promising, the study highlights the need for improved annotation strategies and further research to incorporate this technology into real operating theaters.

Indexed as

Artificial IntelligenceHepatectomyLaparoscopyLiverSurgery, Computer-AssistedDeep LearningFemaleHumansLiver TransplantationLiving DonorsMaleMiddle AgedArtificial intelligenceComputer-assistedComputer-assisted surgeryImage processingLiver transplantationMinimally invasive surgical procedures

Identifiers

PMID40744949
PMCPMC12314017

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.