ArticleThe international journal of cardiovascular imaging2025
Improved prediction of permanent pacemaker implantation in TAVR for aortic regurgitation: integrating Self-expanding valve implants with 3D printed Patient-specific aortic root models and sensors.
Article in The international journal of cardiovascular imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aim of this study is to develop a comprehensive predictive model for PPMI after transcatheter aortic valve replacement (TAVR) in patients with aortic regurgitation by reflecting pressure changes in the critical region post-TAVR using 3D-printed root models equipped with pressure sensors, in conjunction with clinical baseline characteristics, MDCT findings, procedural factors. A retrospective analysis was performed on seventy-two patients with aortic regurgitation who performed pre-TAVR CT evaluation using self-expandable valves. The study excluded patients with a pre-existing PPMI or those who underwent surgical aortic valve replacement. The primary endpoint was in-hospital PPMI following TAVR. Pressure sensors integrated into 3D printed models of aortic root were utilized to visualize pressure in critical regions during TAVR simulation.Additionally, Baseline data, MDCT, and procedural outcomes were collected and analyzed according to established criteria. Multivariable logistic regression models were employed to identify the relationship between variables and the risk of PPMI. The new PPMI rate was 17.9%.The study validated the efficacy of using 3D-printed aortic root models with pressure sensors in predicting the risk of PPMI. On multivariate analysis, the maximum contact pressure, LVOT/annulus area ratio,△MSID and pre-existing RBBB were independent predictors of PPMI. A combination of these factors significantly increased the risk of PPMI post-TAVR. The 3D-printed model of aortic root with pressure sensors provides a valuable tool for visualizing pressure in critical regions and enhancing risk assessment in TAVR procedures.The study highlights the significance of integrating various clinical, anatomical, and procedural factors to predict PPMI risk accurately.
Indexed as
Identifiers
40742634What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.