Heat generation during osteotomy performed with ultrasonic insert versus rotary instrument in bovine femur: ex vivo comparison.

Jéssica B Borges, Antonio C Aloise, Luis Gs Macedo, Marcelo L Teixeira, Peter K Moy, André A Pelegrine

Abstract readComparative Study
In one paragraph

Article in Acta odontologica latinoamericana : AOL, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jéssica B BorgesFaculdade de Odontologia São Leopoldo Mandic, Departamento de Implantodontia. Campinas, SP, Brasil. jessica.bb@live.com.ORCID 0009-0009-0337-1433
Antonio C AloiseFaculdade de Odontologia São Leopoldo Mandic, Departamento de Implantodontia. Campinas, SP, Brasil.ORCID 0000-0002-9318-7956
Luis Gs MacedoFaculdade de Odontologia São Leopoldo Mandic, Departamento de Implantodontia. Campinas, SP, Brasil.ORCID 0000-0002-0052-941X
Marcelo L TeixeiraFaculdade de Odontologia São Leopoldo Mandic, Departamento de Implantodontia. Campinas, SP, Brasil.ORCID 0000-0001-9916-5777
Peter K MoyDepartment of Oral & Maxillofacial Surgery, University of California, Los Angeles, USA.ORCID 0000-0003-2583-9868
André A PelegrineFaculdade de Odontologia São Leopoldo Mandic, Departamento de Implantodontia. Campinas, SP, Brasil.ORCID 0000-0001-7935-1062

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Osteotomy procedures in dentistry are usually performed with drills, but piezosurgical instruments have also been used to improve surgical conditions for both the patient and the operator. This ex vivo study uses infrared thermography to analyze heat generation in osteotomies.

aimThe aim of this study was to conduct an infrared thermographic comparison of the heat generated by an ultrasonic insert, either with or without an aerosol dispersion control device, in contrast to a conventional bur, during osteotomy procedures performed on bovine femur specimens. MATERIALS AND

methodOsteotomies were performed on nine bovine femur blocks, with each osteotomy consisting of a linear cut 12 mm long and 3 mm deep. Each block underwent a single cut from each instrument examined. The osteotomies were divided into three groups according to the instrument used: Group CARB, carbide bur #701; Group INS, #SFR4 ultrasonic insert coated with diamond-like carbon (DLC); and Group INS-S, #SFR4 ultrasonic insert coated with DLC in combination with an aerosol dispersion control device ("spray control"). All incisions were standardized using an automated device. Thermal variations (ΔT) were assessed using an infrared thermographic camera. The maximum (Tm) and minimum (T0) temperatures recorded were utilized to calculate ΔT, following the equation: ΔT = Tm - T0. Statistical analyses were conducted using Kruskal Wallis test and Dunn's test for multiple comparisons (p <0.05).

results: The T0 and Tm recorded for INS (21.5°C ± 0.7ºC and 23.2ºC ± 0.7ºC) and INS-S (20.8ºC ± 0.4ºC and 21.8ºC ± 0.4ºC) were significantly higher (p <0.05) than for CARB (14.9ºC ± 0.8ºC and 17.6ºC ± 1.1ºC, respectively). The observed ΔT for INS (1.7ºC ± 0.4ºC) and INS-S (1.0ºC ± 0.4) were significantly lower (p <0.05) than for CARB (2.7ºC ± 1.1ºC). No significant difference in ΔT was observed for the other comparisons.

conclusionsINS and INS-S produced significantly higher temperatures than CARB. Use of the "spray control" device resulted in a reduction of the temperature variation observed for the piezoelectric insert.

Indexed as

FemurHot TemperatureOsteotomyAnimalsCattleDental InstrumentsIn Vitro TechniquesThermographydental implantsfemurosteotomypiezosurgerythermography

Identifiers

PMID40741802
PMCPMC12317769

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.