Joint Estimation of Anatomy and Implants in X-ray CT using a Mixed Prior Model.

Xiao Jiang, Grace J Gang, J Webster Stayman

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. One-Step Material Decomposition Using Spectral Diffusion Posterior Sampling in Sparse-View Dual-Layer CT.Proceedings of SPIE--the International Society for Optical Engineering · 2026
    Article
  3. Joint CT reconstruction of anatomy and implants using a mixed prior model.Journal of medical imaging (Bellingham, Wash.) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Xiao JiangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD, 21205, USA.
Grace J GangDepartment of Radiology, University of Pennsylvania, Philadelphia PA, 19104, USA.
J Webster StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD, 21205, USA.

Funding

Patient-specific, high-sensitivity spectral CT for assessment of pancreatic cancerR01EB030494 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI GANG, JIANAN GRACE, NOËL, PETER B · 2021 to 2024
$2.4M
NIBIB NIH HHS R01 EB030494
6 · The paper itself

Abstract

Medical implants are often made of dense materials and pose great challenges to accurate CT reconstruction and visualization, especially in regions close to or surrounding implants. Moreover, it is common that diagnostics involving implanted patients require distinct visualization strategies for implants and anatomy indvidually. In this work, we propose a novel approach for joint estimation of anatomy and implants as separate image volumes using a mixed prior model. This prior model leverages a learning-based diffusion prior for the anatomy image and a simple 0-norm sparsity prior for implants to decouple the two volumes. Additionally, a hybrid mono-polyenergetic forward model is employed to effectively accommodate the spectral effects of implants. The proposed reconstruction process alternates between two steps: Diffusion posterior sampling is used to update the anatomy image, and classic optimization updates to the implant image and associated spectral coefficients. Evaluation in spine imaging with metal pedicle screw implants demonstrates that the proposed algorithm can achieve accurate decompositions. Moreover, anatomy reconstruction between the two pedicle screws, an area where all competing algorithms typically fail, is successful in visualizing details. The proposed algorithm also effectively avoids streaking and beam hardening artifacts in soft tissue, achieving 15.25% higher PSNR and 24.29% higher SSIM compared to normalized metal artifacts reduction (NMAR). These results suggest that mixed prior models can help to separate spatially and spectrally distinct objects that differ from standard anatomical features in ordinary single-energy CT to not only improve image quality but to enhance visualization of the two distinct image volumes.