Evidence map›Paper›PMID 40741013›Full record

ArticleWorld journal of cardiology2025

Artificial intelligence-assisted compressed sensing CINE enhances the workflow of cardiac magnetic resonance in challenging patients.

Huaijun Wang, Anne Schmieder, Mary Watkins, Pengjun Wang, Joshua Mitchell, S Zyad Qamer, Gregory Lanza

Abstract read
In one paragraph

Article in World journal of cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Huaijun WangUnited Imaging Healthcare, Houston, TX 77054, United States.
Anne SchmiederDivision of Cardiology, Washington University in Saint Louis, Saint Louis, MO 63108, United States.
Mary WatkinsDivision of Cardiology, Washington University in Saint Louis, Saint Louis, MO 63108, United States.
Pengjun WangDivision of Cardiology, Washington University in Saint Louis, Saint Louis, MO 63108, United States.
Joshua MitchellDivision of Cardiology, Washington University in Saint Louis, Saint Louis, MO 63108, United States.
S Zyad QamerDivision of Cardiology, Washington University in Saint Louis, Saint Louis, MO 63108, United States.
Gregory LanzaDivision of Cardiology, Washington University in Saint Louis, Saint Louis, MO 63108, United States. gmlanza@wustl.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA key cardiac magnetic resonance (CMR) challenge is breath-holding duration, difficult for cardiac patients.

aimTo evaluate whether artificial intelligence-assisted compressed sensing CINE (AI-CS-CINE) reduces image acquisition time of CMR compared to conventional CINE (C-CINE).

methodsCardio-oncology patients (

resultsIn 89 participants (58.5 ± 16.8 years, 42 males, 47 females), total AI-CS-CINE acquisition and reconstruction time (37 seconds) was 84% faster than C-CINE (238 seconds). C-CINE required repeats in 23% (20/89) of cases (approximately 8 minutes lost), while AI-CS-CINE only needed one repeat (1%; 2 seconds lost). AI-CS-CINE had slightly lower contrast but preserved structural clarity. Bland-Altman plots and ICC (0.73 ≤

conclusionAI-CS-CINE accelerated CMR image acquisition and reconstruction, preserved anatomical detail, and diminished impact of patient-related motion. Quantitative AI-CS-CINE metrics agreed closely with C-CINE in cardio-oncology patients, including the cardiac amyloidosis cohort, as well as healthy volunteers regardless of left and right ventricular size and function. AI-CS-CINE significantly enhanced CMR workflow, particularly in challenging cases. The strong analytical concordance underscores reliability and robustness of AI-CS-CINE as a valuable tool.

Indexed as

Acquisition timeArtificial intelligenceCardiac functionCardiac magnetic resonanceCardio-oncologyChallenging patientsCINE imagingCompressed sensingImage qualityImaging workflow

Identifiers

PMID40741013
PMCPMC12304818

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.