Evidence map›Paper›PMID 40735475›Full record

ArticleResuscitation plus2025

Paramedic assessment of carotid artery pulsation using pre-recorded ultrasound videos: a comparative analysis of three ultrasound modes.

C Gaik, H Wulf, B Vojnar

Abstract read
In one paragraph

Article in Resuscitation plus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

C GaikDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Giessen and Marburg, Campus Marburg and Philipps University of Marburg, Germany.
H WulfDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Giessen and Marburg, Campus Marburg and Philipps University of Marburg, Germany.
B VojnarDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Giessen and Marburg, Campus Marburg and Philipps University of Marburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This cross-sectional study aimed to determine whether paramedics with limited or no prior ultrasound experience can consistently identify the presence or absence of common carotid artery (CCA) pulsation, as a potential alternative to manual pulse checks during cardiopulmonary resuscitation. Methods: Following a six-minute instructional video, paramedics assessed short pre-recorded ultrasound videos of the CCA acquired in B-mode, M-mode, and Color Doppler. Each of the 93 participants viewed 24 randomized 10-second videos and classified each as showing pulsation or no pulsation. To replicate clinical conditions where manual pulse checks may fail - such as post-resuscitation - videos were recorded during two distinct phases of cardiac surgery: (1) under controlled hypotension and (2) during complete circulatory standstill following aortic clamping. Results: A total of 2232 assessments were analyzed. M-mode: Participants correctly identified CCA pulsation in 95 % (265/279) of assessments. In videos without CCA pulsation, the correct classification of 'no pulsation present' was achieved in 97 % (270/279). B-mode: The presence of CCA pulsation was correctly identified in 78 % (218/279), whereas in 22 % (61/279) of cases, participants incorrectly categorized the video as 'no pulsation present' despite pulsation being present. Conversely, the absence of CCA pulsation was accurately detected in 98 % (635/651) of cases. Color Doppler: CCA pulsation was correctly identified in 99 % (551/558) of assessments. Similarly, in videos without CCA pulsation, participants correctly classified 96 % (185/186) as 'no pulsation present'. Conclusion: Paramedics demonstrated a high level of diagnostic accuracy in identifying both the presence and absence of CCA pulsation using two-dimensional (2D) ultrasound across multiple imaging modes in a controlled study setting. The findings suggest that the combination of Color Doppler and, in particular, M-mode appears to be the most suitable approach for identifying CCA pulsation via ultrasound.

Indexed as

Cardiac arrestCarotid ultrasoundEmergency medical serviceParamedicsPOCUSPulse check

Identifiers

PMID40735475
PMCPMC12305715

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.