ArticleSensors (Basel, Switzerland)2025
A New Device for Measuring Trunk Diameter Variations Using Magnetic Amorphous Wires.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Measuring the small tree trunk variations during the day-night cycle, seasonal cycles, as well as those caused by the plant's growth and health regime is a very important action in horticulture or forestry because by analyzing the collected data, assessments can be made on the health of the trees, but also on the climatic conditions and changes in a certain region. This can be performed with devices called dendrometers. This paper presents a new type of approach to these measurement types in which the trunk volume changes are highly sensitively converted into the axial stress on sensitive elements made of magnetic materials in wire form in which the giant stress impedance effect occurs. Finally, by electronic processing of the signals provided by the sensitive elements, digital words with a decimal value proportional to the diameter variations are obtained. This paper presents the operating principle, the constructive details and the experimental results obtained by testing the device in the laboratory and in-field. The proposed dendrometer, compared to those available commercially, has the advantage of good resolution and sensitivity, good immunity to temperature variations, the possibility of transmitting the result remotely, robustness and low price. Some metrological parameters obtained from the experimental testing are the following: resolution 1.6 µm, linearity 1.4%, measurement range 0 to 5 mm, temperature coefficient 0.012%/°C.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.