ArticleSensors (Basel, Switzerland)2025
Proton Range Measurement Precision in Ionoacoustic Experiments with Wavelet-Based Denoising Algorithm.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Measurement of Percentage Depth-Dose Distributions in Clinical Dosimetry: Conventional Techniques and Emerging Sensor Technologies.Sensors (Basel, Switzerland) · 2026Review
- Bridging Photoacoustic and Protoacoustic Imaging: Material Heterogeneity Effects on Proton Range Verification Using Time-of-Flight Analysis.Bioengineering (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
This work presents the experimental results of a wavelet transform denoising algorithm (WTDA) that improves the ionoacoustic signal-to-noise ratio (SNR) and proton range measurement precision. Ionoacoustic detectors exploit the ultrasound signal generated by pulsed proton beams in energy absorbers (water or the human body) to localize the energy deposition with sub-millimeter precision, with interesting applications in beam monitoring during oncological hadron therapy treatments. By improving SNR and measurement precision, the WTDA allows significant reduction of the extra dose necessary for beam characterization. To validate the WTDA's performance, two scenarios are presented. First, the WTDA was applied to the ionoacoustic signals from a 20 MeV proton beam, where it allowed for increasing the SNR by 17 dB and improving measurement precision by a factor of two. Then, the WTDA was applied to the simulated signals from a 200 MeV clinical beam where, compared to state-of-the-art algorithms, it achieved a -80% dose reduction when achieving the same 30 μm precision and a six-fold precision improvement for the same 17 Gy dose deposition.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.