Evidence map›Paper›PMID 40731817›Full record

ArticleMedicina (Kaunas, Lithuania)2025

High Insertion Torque-Clinical Implications and Drawbacks: A Scoping Review.

Mattia Manfredini, Martina Ghizzoni, Beatrice Cusaro, Mario Beretta, Carlo Maiorana, Francisley Ávila Souza, Pier Paolo Poli

Abstract readScoping Review
In one paragraph

Article in Medicina (Kaunas, Lithuania), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mattia ManfrediniMaxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Policlinico, 20112 Milan, Italy.ORCID 0000-0001-8270-763X
Martina GhizzoniMaxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Policlinico, 20112 Milan, Italy.ORCID 0000-0001-7774-169X
Beatrice CusaroMaxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Policlinico, 20112 Milan, Italy.
Mario BerettaMaxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Policlinico, 20112 Milan, Italy.
Carlo MaioranaMaxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Policlinico, 20112 Milan, Italy.
Francisley Ávila SouzaDepartment of Diagnosis and Surgery, School of Dentistry, São Paulo State University (UNESP), Araçatuba 16015-050, SP, Brazil.ORCID 0000-0002-1427-071X
Pier Paolo PoliMaxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Policlinico, 20112 Milan, Italy.ORCID 0000-0003-3739-1490

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Implant primary stability is a prerequisite for obtaining osseointegration and clinical success. Insertion torque (IT) is measured during implant placement and is expressed in Ncm. It represents the quantification of the frictional force experienced by the implant as it progresses apically through a rotational motion along its axis. Usually, to achieve osseointegration, a value within the range of 20-40 Ncm is desirable. Below a threshold of 20 Ncm, implants have a decrease in survival rate, while implant stability is guaranteed above 20 Ncm. The main goal of this study was to evaluate whether high values of IT affect osseointegration, implant health, and healing, by highlighting the positive and negative effects of IT > 50 Ncm on peri-implant bone, soft tissues, and long-term stability. This scoping review considered randomized clinical trials, observational studies, and cohort studies. Studies failing to meet the predefined inclusion criteria were excluded from the analysis. The review process adhered to the Preferred Reporting Items for Scoping Reviews (PRISMA-ScR) guidelines. Ultimately, a total of 11 studies were included in the final synthesis. Based on the studies included, the literature suggests that high values of IT guarantee adequate primary stability and better osseointegration. However, high IT is significantly associated with greater marginal bone loss, depending on bone density. Accordingly, IT values > 50 Ncm may provoke greater compressive forces with a negative impact on the jawbone. An elevated strain on the bone can induce necrosis and ischemia, due to an alteration of circulation, which in turn is responsible for marginal bone loss and reduced osseointegration. Lack of osseointegration ultimately leads to an early implant failure. As concerns soft tissue recession, a higher decrease is measured in implants placed with high-insertion torque. Nonetheless, additional clinical trials are warranted to assess long-term outcomes, quantify the incidence of these complications, and explore the impact of emerging clinical variables.

Indexed as

Dental Implantation, EndosseousDental ImplantsOsseointegrationTorqueHumansDental Implantsdental implanthigh torqueimplant failureinsertion torquemarginal bone lossperiimplantitisprimary stability

Identifiers

PMID40731817
PMCPMC12297995

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.