Evidence map›Paper›PMID 40731654›Full record

ArticleMicromachines2025

A Dialysis Membrane-Integrated Microfluidic Device for Controlled Drug Retention and Nutrient Supply.

Hajime Miyashita, Yuya Ito, Kenta Shinha, Hiroko Nakamura, Hiroshi Kimura

Abstract read
In one paragraph

Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hajime MiyashitaDepartment of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.
Yuya ItoDepartment of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.
Kenta ShinhaMicro/Nano Technology Center (MNTC), Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.
Hiroko NakamuraMicro/Nano Technology Center (MNTC), Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.
Hiroshi KimuraDepartment of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.ORCID 0000-0003-0623-0248

Funding

Japan Agency for Medical Research and Development JP17be0304201Japan Agency for Medical Research and Development JP22be1004201Japan Society for the Promotion of Science JP18H01849Japan Society for the Promotion of Science JP24K01321
6 · The paper itself

Abstract

Traditional pre-clinical drug evaluation methods, including animal experiments and static cell cultures using human-derived cells, face critical limitations such as interspecies differences, ethical concerns, and poor physiological relevance. More recently, microphysiological systems (MPSs) that use microfluidic devices to mimic in vivo conditions have emerged as promising platforms. By enabling perfusion cell culture and incorporating human-derived cells, MPSs can evaluate drug efficacy and toxicity in a more human-relevant manner. However, standard MPS protocols rely on discrete medium changes, causing abrupt changes in drug concentrations that do not reflect the continuous pharmacokinetics seen in vivo. To overcome this limitation, we developed a Dialysis Membrane-integrated Microfluidic Device (DMiMD) which maintains continuous drug concentrations through selective medium change via a dialysis membrane. The membrane's molecular weight cut-off (MWCO) enables the retention of high-molecular-weight drugs while facilitating the passage of essential low-molecular-weight nutrients such as glucose. We validated the membrane's molecular selectivity and confirmed effective nutrient supply using cells. Additionally, anticancer drug efficacy was evaluated under continuously changing drug concentrations, demonstrating that the DMiMD successfully mimics in vivo drug exposure dynamics. These results indicate that the DMiMD offers a robust in vitro platform for accurate assessment of drug efficacy and toxicity, bridging the gap between conventional static assays and the physiological complexities of the human body.

Indexed as

co-culturedialysis membranedrug assaymicrofluidic devicemicrophysiological systems

Identifiers

PMID40731654
PMCPMC12299900

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.