ArticleMaterials (Basel, Switzerland)2025
Time-Domain Impedance Analysis on Passivation Quality of 316L Stainless Steel with Portable-Probe-Measured Potential Step Transient.
Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To achieve rapid detection of stainless steel passivation quality, a time-domain impedance method was investigated based on a potential step transient with a portable three-electrode probe. A comparison of the effects of signal analysis and transient parameters was conducted, and the results were compared with those obtained in a bulk solution with a general three-electrode system. The measured transient current with the probe offered a higher signal-to-noise ratio, with minimal deviation from the frequency-domain impedance observed at a step amplitude of 0-100 mV. Measurements using the three-electrode probe under different stabilization times indicated that, after 30 s of stabilization, the measurement deviation was less than 1%, enabling a rapid assessment. Comparative testing of surfaces with varying passivation quality revealed that the pitting potential increases with increasing time-domain impedance, demonstrating the method's capability to distinguish passivated surfaces with different corrosion resistances.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.