Evidence map›Paper›PMID 40730833›Full record

ArticleScientific reports2025

Feasibility test of 3 dimensional patient specific quality assurance of gamma knife radiosurgery using novel mobile phospor probe system.

Minsik Lee, KyoungJoon Yoon, Jun-Bong Shin, BongHyo Lee, Jungwon Kwak, DoHeui Lee

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Minsik LeeDepartment of Radiation Oncology, Kangwon National University Hospital, 156, Baengnyeong-ro, Chuncheon-si, 24289, Gangwon-do, Korea.
KyoungJoon YoonDepartment of Radiation Oncology, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Korea.
Jun-Bong ShinDepartment of Radiation Oncology, Kangwon National University Hospital, 156, Baengnyeong-ro, Chuncheon-si, 24289, Gangwon-do, Korea.
BongHyo LeeDepartment of Physics, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongbuk, 38541, Korea.
Jungwon KwakDepartment of Radiation Oncology, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Korea. jwkwak0301@gmail.com.
DoHeui LeeDepartment of Radiation Oncology, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Korea. doheui@amc.seoul.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study evaluates a novel three-dimensional (3D) quality assurance (QA) device, the Mobile Phosphor Probe (MPP), for pretreatment dose verification in Gamma Knife (GK) stereotactic radiosurgery. The MPP system consists of a cylindrical phantom with a phosphor screen, an imaging unit with a charge-coupled device (CCD) camera, and a motorized driving unit. Dose distributions are reconstructed from images using a lookup table, which correlates CCD pixel optical density with dose values, calibrated against EBT3 film readings. Results show that the full width at half maximum of normalized dose distributions between film and CCD were consistent within a 0.2 mm margin. A 3D dose distribution was constructed by stacking two-dimensional images obtained at 0.3 mm intervals over a ± 30 mm range in the superior-inferior direction. Validation was achieved by comparing the reconstructed 3D doses with planned distributions across multiple planes using gamma evaluation. All cases within the 20-80% isodose line (IDL) range achieved a 95% gamma passing rate under 2.0%/2.0 mm criteria, and the 1.0%/1.0 mm criteria were met at the 50% IDL in all dimensions. The MPP system demonstrates potential as an efficient patient-specific QA tool for GK radiosurgery, offering a streamlined alternative to traditional film dosimetry.

Indexed as

Imaging, Three-DimensionalQuality Assurance, Health CareRadiosurgeryFeasibility StudiesHumansPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-Assisted3D patient specific QAGamma knifeMobile phosphor probeRadiosurgery

Identifiers

PMID40730833
PMCPMC12307658

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.