ArticlePloS one2025
Fault analysis and performance improvement of grid-connected doubly fed induction generator through an enhanced crowbar protection scheme.
Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The main problem associated with a doubly fed induction generator (DFIG) during fault is large inrush currents induced in rotor winding, which has detrimental effects on the machine's AC excitation converter. A simple conventional resistance inclusion (crowbar) is employed with a PI controller to protect a DFIG from transient current, but it is observed that this method is not enough to keep transient over-current to an admissible level. In this paper, an effective current limiting technique along with reactive power control is proposed in order to maintain stability, reduce transient current surge to an acceptable level, and enhance the Fault Ride Through capacity of DFIG. The proposed dynamic control technique not only limits the fault current during voltage dip to a permissible level but also controls the reactive power during fault. The behavior of a proposed technique is analyzed by introducing unsymmetrical faults in the MATLAB-based model of DFIG. An enhanced crowbar-based fault ride-through is employed for the rotor side controller to limit inrush current and control reactive power.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.