Evidence map›Paper›PMID 40729319›Full record

ArticlePloS one2025

Myoconjunctival Enucleation Study (MES): Outcome of Myoconjunctival Enucleation Technique with Polymethyl Methacrylate (PMMA) implant and Custom-made prosthesis (CMP) in a tertiary eye care center in Nepal.

Hom Bahadur Gurung, Purnima Rajkarnikar Sthapit, Malita Amatya, Dikshya Bista, Sushant Adiga, Manish Poudel, Raba Thapa, Rohit Saiju

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hom Bahadur GurungDepartment of Oculoplasty and Ocular Oncology, Tilganga Institute of Ophthalmology, Kathmandu, Nepal.ORCID 0000-0001-5948-5266
Purnima Rajkarnikar SthapitDepartment of Oculoplasty and Ocular Oncology, Tilganga Institute of Ophthalmology, Kathmandu, Nepal.
Malita AmatyaDepartment of Oculoplasty and Ocular Oncology, Tilganga Institute of Ophthalmology, Kathmandu, Nepal.
Dikshya BistaDepartment of Oculoplasty and Ocular Oncology, Tilganga Institute of Ophthalmology, Kathmandu, Nepal.
Sushant AdigaDepartment of Oculoplasty and Ocular Oncology, Tilganga Institute of Ophthalmology, Kathmandu, Nepal.ORCID 0000-0001-6794-5891
Manish PoudelDepartment of Research and Biostatistics, Tilganga Institute of Ophthalmology, Kathmandu, Nepal.
Raba ThapaDepartment of Oculoplasty and Ocular Oncology, Tilganga Institute of Ophthalmology, Kathmandu, Nepal.
Rohit SaijuDepartment of Oculoplasty and Ocular Oncology, Tilganga Institute of Ophthalmology, Kathmandu, Nepal.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the average motility of the implant and custom-made prosthesis (CMP) in various gazes following Myoconjunctival enucleation, the surgical duration, and the complications encountered at a tertiary eye hospital.

methodsThis was a prospective, non-randomized interventional study. Recti muscles were sutured to the fornices before enucleation of the eyeball to minimize surgical time and the need for additional sutures. Thirty-five consecutive patients meeting the inclusion criteria were enrolled. Data on surgery time, complications, and implant/prosthesis motility were recorded and analyzed.

resultsThe mean surgical duration was 39.43 ± 4.97 minutes. Mean PMMA implant movement was 2.34 mm in elevation, 2.26 mm in depression, 2.74 mm in abduction, and 2.71 mm in adduction. Custom-made prosthesis (CMP) movement was 2.40 mm in elevation, 2.51 mm in depression, 2.74 mm in abduction, and 2.66 mm in adduction. Complications were minimal: one intraoperative superior rectus slippage, a few cases with early postoperative nausea, vomiting, and headache, all resolved within a week. At six weeks, one suture granuloma and one shallow inferior fornix were noted and managed. Patient satisfaction was high (88.57%), with a mean Likert score of 4.25 ± 0.65 (1 = Very unsatisfied to 5 = Very satisfied). No patient reported dissatisfaction.

conclusionMyoconjunctival enucleation offers favorable implant and prosthesis motility, a relatively short surgical duration, and minimal complications. High patient satisfaction supports the myoconjunctival enucleation technique as a reliable and well-tolerated surgical option.

Indexed as

ConjunctivaEye EnucleationPolymethyl MethacrylateProstheses and ImplantsAdultAgedEye, ArtificialFemaleHumansMaleMiddle AgedNepalProspective StudiesTertiary Care CentersTreatment OutcomePolymethyl Methacrylate

Identifiers

PMID40729319
PMCPMC12306768

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.