Evidence map›Paper›PMID 40729209›Full record

ArticleReports (MDPI)2023

Transvenous Lead Extraction in a European Low-Volume Center without On-Site Surgical Support.

Mohamed Dardari, Corneliu Iorgulescu, Vlad Bataila, Alexandru Deaconu, Eliza Cinteza, Radu Vatasescu, Paul Padovani, Corina Maria Vasile, Maria Dorobantu

Abstract read
In one paragraph

Article in Reports (MDPI), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mohamed DardariDepartment of Cardiology, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania.ORCID 0000-0002-9960-9216
Corneliu IorgulescuElectrophysiology and Cardiac Pacing Lab, Clinical Emergency Hospital, 014461 Bucharest, Romania.
Vlad BatailaDepartment of Cardiology, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania.
Alexandru DeaconuDepartment of Cardiology, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania.
Eliza CintezaDepartment of Pediatrics, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania.ORCID 0000-0003-3239-0704
Radu VatasescuDepartment of Cardiology, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania.ORCID 0000-0001-7163-8528
Paul PadovaniDepartment of Pediatric Cardiology and Pediatric Cardiac Surgery, Nantes Université, CHU Nantes, FHU PRECICARE, F-44000 Nantes, France.ORCID 0000-0001-6170-3103
Corina Maria VasilePediatric and Adult Congenital Cardiology Department, M3C National Reference Centre, Bordeaux University Hospital, F-33000 Bordeaux, France.ORCID 0000-0002-4684-8213
Maria DorobantuDepartment of Cardiology, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Indications for cardiac implantable electronic devices (CIEDs) are increasing. Almost one-third of device-related infections are endocarditis. Transvenous lead extraction (TLE) has emerged as an effective and safe approach for treating device-related infections and complications. Multiple types of extraction tools are being used worldwide. Our goal is to evaluate the safety and effectiveness of TLE using non-powered extraction tools. The study included patients between October 2018 and July 2022 requiring TLE according to EHRA expert consensus recommendations on lead extraction. A total of 88 consecutive patients were included. Indications for TLE included device-related infections in 74% of the patients. Of those, 32% had device-related endocarditis with or without sepsis. Staphylococcus Aureus was the most frequent pathogen in patients with endocarditis and positive bacteremia, and 57% had negative bloodstream cultures. A total of 150 cardiac pacing and defibrillator leads were targeted for extraction. The mean dwell time for leads was 6.92 ± 4.4 years; 52.8% were older than 5 years, 15.8% were older than ten years, and the longest lead dwell time was 26 years. Patients' age varied between 18 and 98, with a mean age of 66 ± 16 years. Sixty-seven percent of patients were males. Using only non-powered extraction tools, we report 93.3% complete lead removal and 99% clinical success with partial extraction. We report no procedure-related death nor major complications. Minor complication incidence was 6.8%, and all complications resolved spontaneously. The 30-day mortality rate was 3.4%. TLE using non-powered extraction tools is safe and effective even without surgical backup on site.

Indexed as

cardiac implantable electronic devicedefibrillatordevice-related endocarditisnon-powered lead extraction sheathspacemakerpocket infectiontransvenous lead extraction

Identifiers

PMID40729209
PMCPMC12225247

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked