ArticleAbdominal radiology (New York)2026
Comparison of iodine quantification accuracy on prototype deep silicon photon-counting and energy-integrating detector CT.
Article in Abdominal radiology (New York), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis work examined the iodine quantification accuracy on a prototype deep silicon (dSi) photon-counting detector (PCD) computed tomography (CT) system compared to a rapid kV switching energy-integrating detector (EID) dual-energy (DE) CT system.
methodsIodine-containing rods (0-20 mg I/mL) in a phantom (Gammex MECT) were scanned with the prototype dSi PCD and DECT systems. Iodine (water) material density images were made with prototype and commercially available material decomposition algorithms, respectively. Circular regions of interest were placed over the center of the iodine rods to measure iodine accuracy in each slice, and slices were averaged. A correction based on the known issue of background material difference from true water was determined from the 0 mg I/mL (solid water) rod and the relative rod densities and was applied to the iodine quantification. Iodine percent error was defined as the difference between corrected iodine quantification and known iodine quantification, divided by the known iodine, multiplied by 100.
resultsThe corrected iodine quantification was within 0.15 mg I/mL for 0-20 mg I/mL iodine rods on the prototype PCD CT and 0.2 mg I/mL for the EID DECT. This translates to iodine percent errors of 0.4-4.3% on the PCD CT and 1.1-76% on the EID DECT for 0.2-20 mg I/mL rods.
conclusionIodine quantification on the prototype dSi PCD CT was within 4.3% for all tested iodine-containing rods, which is similar or better than the performance of the EID DECT system and previous work on the prototype dSi system.