Time Required for Extubation While Using Bispectral Index Monitoring Compared to End-Tidal Anesthetic Gas Concentration in Patients Undergoing General Anesthesia.

Amithkumar Sk, Deepak V Kadlimatti, Santosh Kumar, Palla Sree Divya, Mithra Ajith

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Amithkumar SkDepartment of Anaesthesiology, Dr. B.R. Ambedkar Medical College & Hospital, Bengaluru, IND.
Deepak V KadlimattiDepartment of Anaesthesiology, Dr. B.R. Ambedkar Medical College & Hospital, Bengaluru, IND.
Santosh KumarDepartment of Anaesthesiology, Dr. B.R. Ambedkar Medical College & Hospital, Bengaluru, IND.
Palla Sree DivyaDepartment of Anaesthesiology, Dr. B.R. Ambedkar Medical College & Hospital, Bengaluru, IND.
Mithra AjithDepartment of Anaesthesiology, Dr. B.R. Ambedkar Medical College & Hospital, Bengaluru, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe objective of this study was to compare extubation timings between patients monitored with the bispectral index (BIS) and those monitored using end-tidal anesthetic gas (ETAG) to determine which method provides a more efficient recovery profile. METHODOLOGY: A prospective observational study was conducted on 50 patients aged 18 to 60 years, classified as American Society of Anesthesiologists (ASA) physical status I-II, undergoing elective surgeries under general anesthesia (GA). Patients were randomized into BIS and non-BIS (ETAG) groups to assess anesthetic consumption and recovery characteristics. Standard anesthetic protocols were followed. In the BIS group, BIS values were maintained between 40 and 60, while in the ETAG group, end-tidal isoflurane concentrations were kept between 0.7 and 1.3 minimum alveolar concentration (MAC). Intraoperative parameters and extubation times were recorded. Isoflurane administration was discontinued at the time of skin closure, and neuromuscular blockade was reversed once a train-of-four (TOF) ratio greater than 0.9 was confirmed. Data were analyzed using SPSS version 26.0 (IBM Corp., Armonk, NY), with a p-value less than 0.05 considered statistically significant.

resultsThere was no statistically significant difference in the overall duration of anesthesia between the two groups (p > 0.05). However, the BIS group had a significantly shorter extubation time, averaging 148.4 ± 30.5 seconds, compared to 201.2 ± 43.6 seconds in the ETAG group. The mean difference was 52.8 ± 13.1 seconds (p = 0.001). Additionally, the average hourly isoflurane consumption was significantly lower in the BIS group (5.9 ± 0.77 mL) compared to the ETAG group (6.56 ± 1.12 mL), with a mean difference of 0.66 ± 1.04 mL (p = 0.01).

conclusionExtubation occurred significantly earlier in patients monitored with BIS than in those observed with ETAG. Furthermore, BIS-guided anesthesia was associated with reduced isoflurane consumption compared to ETAG-guided monitoring.

Indexed as

bispectral indexend-tidal anestheticextubation timegas concentrationisoflurane

Identifiers

PMID40718286
PMCPMC12294680

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked