ArticleACS sensors2025
Minimally Invasive and in Situ Capacitive Sensing of Cardiac Troponin I from Interstitial Fluid.
Article in ACS sensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Continuous Molecular Monitoring Using Electrochemical Aptamer-Based Sensors: Remaining Challenges for Long-Term In Vivo Deployment.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- Smart wearable biosensors: a transformative synergy between diagnosis and treatment of disease.RSC advances · 2026Review
- Biosensor-Integrated Microneedle Devices for Diagnosis and Treatment of Chronic and Infectious Diseases: Current Status, Trends and Challenges.Biosensors · 2026Review
- Beyond glucose: wearable and implantable biosensors for continuous monitoring of metabolic, hormonal, and inflammatory biomarkers in personalized cardiometabolic care.Frontiers in bioengineering and biotechnology · 2026Review
- The detection of cardiovascular biomarkers in dermal interstitial fluid - a step to real-time monitoring.Frontiers in cardiovascular medicine · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Current diagnostic approaches for myocardial infarction (MI) rely on blood-based cardiac biomarker analysis by centralized instruments, often delaying timely clinical decisions. We present a microneedle-based capacitive biosensor (MiCaP) for in situ minimally invasive monitoring of cardiac troponin I (cTnI) in interstitial fluid (ISF) for point-of-care (POC) applications. MiCaP is a label-free biosensor operating based on nonfaradaic sensing by monitoring electric double layer capacitance at the microneedle-ISF interface. We extracted a simplified equivalent circuit model for MiCaP inserted into the skin, confirming that the measured capacitance variations originate from cTnI binding to surface-immobilized antibodies. MiCaP was fabricated by using a scalable process and functionalized with anti-cTnI antibodies. In vitro measurements showed a dynamic detection range of 10 pg/mL to 10 ng/mL, a limit of detection (LOD) of 3.27 pg/mL, and a total assay response time of less than 15 min. A spike-and-recovery test using cTnI-spiked human serum yielded a recovery accuracy exceeding 93%. In vivo studies in rats demonstrated ISF cTnI levels of 3 ± 0.4 pg/mL in controls and 912 ± 683 pg/mL in experimental animals, indicating an increasing trend consistent with serum concentrations measured using a clinical immunoassay. These results support the potential of MiCaP as a minimally invasive biosensing platform for cardiac biomarker monitoring, with possible extension to multiplexed ISF-based diagnostics in the POC.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.