Evidence map›Paper›PMID 40712048›Full record

ArticleInterdisciplinary cardiovascular and thoracic surgery2025

Mid-Term Outcomes After Aortic Valve Replacement in Patients Under 70: A Comparative Study of INSPIRIS RESILIA Versus PERIMOUNT MAGNA EASE Bioprostheses.

Gabriel Saiydoun, Elie Nassar, Saadé Saadé, Chadi Aludaat, Sylvain Rubin, Ibrahim Alqdeimat, Vito Giovanni Ruggieri

Abstract readComparative Study
In one paragraph

Article in Interdisciplinary cardiovascular and thoracic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Gabriel SaiydounDepartment of Cardiac Surgery, Pitié-Salpetrière University Hospital, Sorbonne University, 75013 Paris, France.ORCID 0000-0003-0630-8332
Elie NassarDepartment of Thoracic and Cardiovascular Surgery, Reims University Hospital, 51100 Reims, France.
Saadé SaadéDepartment of Cardiac Surgery, Strasbourg University Hospital, 67000 Strasbourg, France.
Chadi AludaatDepartment of Cardiac Surgery, Rouen University Hospital, 76031 Rouen, France.ORCID 0000-0002-9825-3852
Sylvain RubinDepartment of Thoracic and Cardiovascular Surgery, Reims University Hospital, 51100 Reims, France.
Ibrahim AlqdeimatDepartment of Thoracic and Cardiovascular Surgery, Reims University Hospital, 51100 Reims, France.
Vito Giovanni RuggieriDepartment of Thoracic and Cardiovascular Surgery, Reims University Hospital, 51100 Reims, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesINSPIRIS RESILIA, launched in 2017, is a bioprosthetic aortic valve developed to improve durability and facilitate future valve-in-valve procedures. Despite its advanced design, many surgeons continue to use the PERIMOUNT MAGNA EASE valve, which has long-standing clinical validation. This study aimed to compare mid-term clinical and echocardiographic outcomes in patients under 70 undergoing aortic valve replacement with either prosthesis.

methodsWe conducted a retrospective study of patients who underwent surgical aortic valve replacement between January 2018 and May 2023 at the University Hospital of Reims. The primary outcome was all-cause mortality at 1 year following surgical aortic valve replacement. Secondary outcomes included haemodynamic parameters, left ventricular ejection fraction, and major postoperative complications such as reintervention, stroke, pacemaker implantation, mediastinitis, transfusion, and new-onset atrial fibrillation.

resultsA total of 300 patients were included: 52 received the INSPIRIS RESILIA valve and 248 received the PERIMOUNT MAGNA EASE valve. After matching, 52 patients from each group were compared. All-cause mortality at 3 years was 0% in the INSPIRIS group and 1.9% in the PERIMOUNT group. Mean transvalvular gradients were similar at 1 year (11.3 vs 11.2 mmHg) and 3 years (12.9 mmHg for both). Two cases of endocarditis-related reoperation occurred in the INSPIRIS group. No structural valve degeneration requiring surgery was observed. Postoperative aortic regurgitation was trivial or absent. Transfusion rates were lower in the INSPIRIS group (46.1% vs 69.2%, P = .017).

conclusionsINSPIRIS RESILIA and MAGNA EASE valves offer similar mid-term safety and performance in patients under 70 years of age.

Indexed as

Aortic ValveAortic Valve StenosisBioprosthesisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationAdultAgedAge FactorsFemaleHumansMaleMiddle AgedPostoperative ComplicationsProsthesis DesignRetrospective StudiesRisk Factorsaortic stenosisaortic valve replacementINSPIRIS RESILIAPERIMOUNT MAGNA EASE

Identifiers

PMID40712048
PMCPMC12342774

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.