Evidence map›Paper›PMID 40711342›Full record

ArticleVeterinary sciences2025

Finite Element Analysis of Stress Distribution in Canine Lumbar Fractures with Different Pedicle Screw Insertion Angles.

Ziyao Zhou, Xiaogang Shi, Jiahui Peng, Xiaoxiao Zhou, Liuqing Yang, Zhijun Zhong, Haifeng Liu, Guangneng Peng, Chengli Zheng, Ming Zhang

Abstract read
In one paragraph

Article in Veterinary sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ziyao ZhouTeaching Veterinary Hospital, College of Veterinary Medicine, Sichuan Agricultural University, Chengdu 611130, China.
Xiaogang ShiSichuan Wolong National Natural Reserve Administration Bureau, Wenchuan 623006, China.
Jiahui PengTeaching Veterinary Hospital, College of Veterinary Medicine, Sichuan Agricultural University, Chengdu 611130, China.
Xiaoxiao ZhouChengdu Center for Animal Disease Prevention and Control, Chengdu 610041, China.
Liuqing YangSichuan Institute of Musk Deer Breeding, Sichuan Institute for Drug Control, Chengdu 611130, China.
Zhijun ZhongTeaching Veterinary Hospital, College of Veterinary Medicine, Sichuan Agricultural University, Chengdu 611130, China.
Haifeng LiuTeaching Veterinary Hospital, College of Veterinary Medicine, Sichuan Agricultural University, Chengdu 611130, China.
Guangneng PengTeaching Veterinary Hospital, College of Veterinary Medicine, Sichuan Agricultural University, Chengdu 611130, China.ORCID 0000-0002-9898-5754
Chengli ZhengSichuan Institute of Musk Deer Breeding, Sichuan Institute for Drug Control, Chengdu 611130, China.ORCID 0000-0003-2933-3645
Ming ZhangCollege of Animal Science, Sichuan Agricultural University, Chengdu 611130, China.

Funding

Science and Technology program of the Sichuan Medical Products Administration 2024010
6 · The paper itself

Abstract

Pedicle screw fixation is a critical technique for stabilizing lumbar fractures in canines, yet the biomechanical implications of insertion angles remain underexplored. This study aims to identify optimal screw trajectories by analyzing stress distribution and deformation patterns in beagle lumbar segments (L6-L7) using finite element analysis (FEA). A 3D finite element model was reconstructed from CT scans of a healthy beagle, incorporating cortical/cancellous bone, intervertebral disks, and cartilage. Pedicle screws (2.4 mm diameter, 22 mm length) were virtually implanted at angles ranging from 45° to 65°. A 10 N vertical load simulated standing conditions. Equivalent stress and total deformation were evaluated under static loading. The equivalent stress occurred at screw-rod junctions, with maxima at 50° (11.73 MPa) and minima at 58° (3.25 MPa). Total deformation ranged from 0.0033 to 0.0064 mm, with the highest at 55° and the lowest at 54°. The 58° insertion angle demonstrated optimal biomechanical stability with minimal stress concentration, with 56-60° as a biomechanically favorable range for pedicle screw fixation in canine lumbar fractures, balancing stress distribution and deformation control. Future studies should validate these findings in multi-level models and clinical settings.

Indexed as

biomechanical stabilitycanine lumbar spinefinite element analysisinsertion anglepedicle screw fixation

Identifiers

PMID40711342
PMCPMC12301062

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.