ArticleHeart international2025
Retrospective Comparison of Device Versus Suture for Patent Foramen Ovale Closure.
Article in Heart international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The use of an implantable closure device with medical therapy to prevent recurrent stroke in patent foramen ovale (PFO)-associated stroke has been shown to be superior to medical therapy alone. Recently, an alternative, suture-based method also has shown promise for effective PFO closure. There has been little published data comparing the outcomes of these two technologies. Methods: This retrospective study explores the safety and efficacy outcomes of device-based versus suture-based percutaneous PFO intervention. The occurrence of post-procedural atrial fibrillation was of primary interest. Data from 55 single-institution, single-operator PFO closure cases between 1 January 2021 and 8 April 2022 were analyzed. Closure occurred via one of two Food and Drug Administration (FDA)-approved occluders or the NobleStitch™ EL suture-based approach. Data were transcribed into a registered REDCap database for descriptive analysis. Demographics, medical history, imaging, procedural and post-procedural outcomes were the variables collected for each participant. Results: All patients had successful PFO closure without major adverse outcomes. Overall efficacy was similar between the two groups. No patient had a residual shunt greater than grade 1. Several suture-group patients required multiple sutures for satisfactory closure. Those who had multiple sutures had no anomalous anatomic PFO features. Three patients (5%), all from the device group, developed atrial fibrillation after PFO closure. Conclusions: This study supports the safety and efficacy of device- and suture-based approaches in PFO closure. Suture-based closure would seem a reasonable option where device-based closure raises concerns. Future studies could further explore the observed disparity of atrial fibrillation occurrence between the two PFO closure strategies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.