Evidence map›Paper›PMID 40708615›Full record

ArticleEuropean heart journal. Case reports2025

Successfully escaping the pleura with the extra-vascular implantable cardioverter defibrillator lead: a case report.

Iris Duroi, Reshma Amin, Nicolas Blankoff, El Medhi Channan, Jean-Benoît le Polain de Waroux

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Iris DuroiDepartment of Electrophysiology, AZ Sint-Jan Hospital, Ruddershove 10, Bruges B-8000, Belgium.ORCID https://orcid.org/0000-0001-7756-7927
Reshma AminDepartment of Electrophysiology, AZ Sint-Jan Hospital, Ruddershove 10, Bruges B-8000, Belgium.ORCID https://orcid.org/0000-0002-6254-4674
Nicolas BlankoffDepartment of Electrophysiology, AZ Sint-Jan Hospital, Ruddershove 10, Bruges B-8000, Belgium.ORCID https://orcid.org/0000-0001-9292-6115
El Medhi ChannanDepartment of Electrophysiology, AZ Sint-Jan Hospital, Ruddershove 10, Bruges B-8000, Belgium.
Jean-Benoît le Polain de WarouxDepartment of Electrophysiology, AZ Sint-Jan Hospital, Ruddershove 10, Bruges B-8000, Belgium.ORCID https://orcid.org/0000-0003-1737-1353

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Extra-vascular implantable cardioverter defibrillator (EV-ICD) is an emerging technique for ICD implantation with substernal lead placement. The system avoids the vasculature and can deliver anti-tachycardia and pause prevention pacing, with a generator size smaller than the existing subcutaneous device. While this device is now widely available, little is known about potential complications that may follow its implantation in real life context. Case summary: We report the case of a 46-year-old male with a history of non-ischaemic dilated cardiomyopathy, severely reduced left ventricular ejection fraction, and intravenous drug use who underwent EV-ICD implantation for primary prevention of sudden cardiac death. The device implantation was uncomplicated with initial satisfactory device parameters and fluoroscopic position. However, post-implant chest radiograph demonstrated lead dislodgement. Despite meticulous assessment on post-implantation CT, the exact position of the dislocated lead couldn't be determined with certainty. Lead revision was performed at 1 month following implantation, and fluoroscopic assessment at this time revealed lead movement synchronous with respiration, raising suspicion that the lead was intra-pleural. A sheath was repositioned over the dislocated lead and contrast injected. Contrast dispersion confirmed the intra-pleural positioning of the lead and was subsequently used as landmark for the appropriate substernal retunnelling of the lead. At most recent follow-up, lead position on chest radiograph and device parameters were satisfactory. Discussion: Extra-vascular implantable cardioverter defibrillator lead placement and dislodgement within the pleural space can follow apparently uncomplicated implantation. Both cine-imaging and contrast injection can be used for accurate assessment of the lead position relative to the pleura and help successful reimplantation.

Indexed as

Case reportComplicationDislocationEV-ICDLead extractionPleura

Identifiers

PMID40708615
PMCPMC12287926

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.