Evidence map›Paper›PMID 40708516›Full record

ReviewRecent patents on biotechnology2026

Recent Patents of Stent Grafts for Intravascular Aortic Repair.

Yiwen Wang, Yuxin Zhang

Abstract readReview
PubMed Publisher
In one paragraph

Review in Recent patents on biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Yiwen WangKey Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin, P. R. China.ORCID 0000-0002-1623-3787
Yuxin ZhangCollege of Mechanical and Power Engineering, Harbin University of Science and Technology, Harbin, P. R. China.

Funding

National Natural Science Foundation of China 51875143
6 · The paper itself

Abstract

introductionEndovascular aortic repair involves the placement of stents through minimally invasive methods to seal rupture sites near the aortic inflow tract, thereby preventing blood entry into the false lumen and promoting thrombosis, which reduces the risk of aortic rupture. Endovascular stents typically consist of a metal framework and a flexible membrane graft designed to reopen obstructed aortic segments and maintain blood flow through the true lumen. Consequently, stents are widely used to treat aortic expansion diseases and aortic occlusive stenosis. However, traditional stents have limitations in terms of adaptability to complex anatomical structures, long-term durability, biomechanical stability, and reliance on radial support force for fixation, lacking active fixation mechanisms. These shortcomings remain the primary causes of postoperative complications, significantly impacting the quality of life for patients with aortic dissection.

methodsIntegrating patent and academic literature, the research status of the endovascular stent was discussed in depth, and the main factors for the optimal design of the stent (geometry, pattern configuration, additional fixtures, and optimization methods) were analyzed and summarized according to the complications targeted by the repair device.

resultsThe composition structure, working principle, and development status of the stent grafts under review are elaborated in detail. Stent grafts attempt to alleviate postoperative complications through three approaches: enhancing the flexibility of the stent framework, improving the fit between the vessel wall and the stent, and reducing vascular injury. Blood flow guiding channels are established to alleviate the obstruction of branch blood flow. Additional self-anchoring devices are added to adapt to the dynamic remodeling of blood vessels. DISCUSSION: The effects of various factors, including geometric parameters, structural design, and parameter optimization techniques, on the optimization of stent primary mechanical performance are discussed. The current research status of functional improvement methods for stents is also summarized.

conclusionRefining the quantitative relationship between stent structural parameters and mechanical performance, as well as exploring the balance criteria between flexibility and radial support force, represent promising directions for future development. These objectives necessitate further in-depth analysis and research.

Indexed as

AortaBlood Vessel ProsthesisEndovascular ProceduresStentsBlood Vessel Prosthesis ImplantationHumansPatents as TopicProsthesis Designaortic dissectionendovascular aortic repairendovascular aortic repair complicationstent-graft designstent optimizationVascular

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.