ArticlePloS one2025
A dual-plane fluoroscope to track joint kinematics during dynamic daily activities.
Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it.
- In vivo biomechanics after total hip arthroplasty: a state-of-the-art systematic review.EFORT open reviews · 2026Pooled it
- Individualized multimodal integration of optimized dual fluoroscopic imaging registration and finite element modeling for knee joint stress during stair ascent.Medical & biological engineering & computing · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Accurate measurement of joint kinematics is a key requirement for understanding injury mechanisms, evaluate rehabilitation techniques, and improve the implant designs and techniques used in total knee arthroplasty (TKA). Fluoroscopy is an experimental technique to directly measure joint kinematics without being affected by soft-tissue artefacts. However, because of its limited field-of-view (FOV), stationary fluoroscopy can only measure small parts of more dynamic/progressive movements, such as walking. This manuscript presents a new generation of moving fluoroscope: The tracking dual-plane fluoroscope (tDPF) combines optical tracking with a bi-planar X-ray system on mechanically independent source and intensifier carriages on rails and model-predictive-control to measure the kinematics of the tibio-femoral joint in vivo during dynamic activities, such as level walking and stair ascent/descent, at all gait speeds. In this proof-of-concept study, the tDPF tracked the knees of 16 young and healthy subjects during complete, consecutive gait cycles of level walking, ramp ascent, ramp descent, stair ascent, and stair descent at self-selected gait speeds. For all gait speeds (average and standard deviation: [Formula: see text] during level walking), tracking performance for each activity was excellent and the knee centre stayed within both simulated image intensifiers' FOVs for [Formula: see text] of frames (no X-ray images were captured in this study). The tDPF is the first dual-plane fluoroscope to track the knee joint during entire cycles of stair and ramp ascent at self-selected gait speeds for young and healthy subjects. Notably, our device does not require any pre-recording of movement patterns-by using real-time position estimates of the tracked joint and tracking each trial independently, even the challenging measurements of tasks with high variability between trials become possible.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.