Evidence map›Paper›PMID 40703773›Full record

ArticleFrontiers in neurology2025

Impact of stent retriever diameter on clinical outcomes in mechanical thrombectomy: a multicenter comparison of the 4-mm and 6-mm Solitaire devices.

Jung Hyun Park, Hoon Kim, Sunghan Kim

Abstract read
In one paragraph

Article in Frontiers in neurology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jung Hyun ParkDepartment of Neurosurgery, Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Republic of Korea.
Hoon KimDepartment of Neurosurgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Sunghan KimDepartment of Neurosurgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Optimal stent retriever diameter for mechanical thrombectomy in large vessel occlusion remains debated. We compared the efficacy and safety of Solitaire 4 × 40 mm and 6 × 40 mm stent retrievers in treating distal internal carotid artery (ICA) or middle cerebral artery (MCA) M1 segment occlusion. Methods: We retrospectively analyzed 145 patients with distal ICA or M1 occlusion treated with the Solitaire 4 × 40 mm ( Results: The 6 × 40 mm group displayed a significantly higher first-pass mTICI ≥2b rate (58.1% vs. 23.7%, Conclusion: The Solitaire 6 × 40 mm stent retriever showed more favorable efficacy outcomes and comparable safety compared to the 4 × 40 mm device for distal ICA or M1 occlusion, suggesting it may be considered a preferred option for these vessels.

Indexed as

cerebral infarctionequipment designstentsthrombectomytreatment outcome

Identifiers

PMID40703773
PMCPMC12283331

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.