Evidence map›Paper›PMID 40703457›Full record

ArticleEwha medical journal2023

Verification of the Performance of the Panbio COVID-19 Ag Rapid Test Device for Implementation in the Clinical Laboratory.

Hae-Sun Chung, Ji Su Chung, Yeo-Jin Lee, Seonwoo Lee, Juhyun Jeong, Min-Kyung So, Miae Lee

Abstract read
In one paragraph

Article in Ewha medical journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hae-Sun ChungDepartment of Laboratory Medicine, Ewha Womans University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-6382-4099
Ji Su ChungDepartment of Medicine, Ewha Womans University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-5070-6437
Yeo-Jin LeeDepartment of Medicine, Ewha Womans University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-6208-3812
Seonwoo LeeDepartment of Medicine, Ewha Womans University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0003-3269-7044
Juhyun JeongDepartment of Medicine, Ewha Womans University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-7838-3310
Min-Kyung SoDepartment of Laboratory Medicine, Ewha Womans University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-9728-3008
Miae LeeDepartment of Laboratory Medicine, Ewha Womans University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-9140-3814

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: The Panbio COVID-19 Ag Rapid Test Device (Panbio COVID-19 Ag, Abbott Rapid Diagnostics) is a lateral flow immunochromatographic assay targeting the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleoprotein in nasopharyngeal specimens for the diagnosis of coronavirus disease 2019 (COVID-19). This study aimed to verify the performance of the Panbio COVID-19 Ag for implementation in clinical laboratories. Methods: Sixty nasopharyngeal swab specimens (30 positive and 30 negative) dipped in transport medium, and COVID-19 was confirmed using real-time RT-PCR using Allplex SARS-CoV-2 assay (Seegene), were tested using the Panbio COVID-19 Ag. Reproducibility was evaluated using positive and negative control materials. Sensitivity and specificity were calculated based on the results of real-time RT-PCR as the standard test method. Results: Reproducibility was confirmed by the consistent results of repeated tests of the quality control materials. The overall sensitivity and specificity of Panbio COVID-19 Ag were 50.0% and 100.0%, respectively. Panbio COVID-19 Ag demonstrated high sensitivity (88.2%) in analyzing the detection limit cycle threshold (Ct) value of 26.67 provided by the manufacturer as a positive criterion, and the sensitivity was 100.0% for the positive criterion of Ct values <25, although it was less sensitive for Ct ≥25. Conclusion: Considering the high sensitivity for positive samples with Ct values <25 and the rapid turnaround of results, Panbio COVID-19 Ag can be used in clinical laboratories to diagnose COVID-19 in limited settings.

Indexed as

COVID-19Rapid antigen detection testSARS-CoV-2Sensitivity

Identifiers

PMID40703457
PMCPMC12093647

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.