Evidence map›Paper›PMID 40703000›Full record

ArticleNMR in biomedicine2025

Ultrahigh-Field MR-Compatible Mechanical Tactile Stimulator for Investigating Somatosensory Processing in Small-Bodied Animals.

Chenyu Wang, Hirohiko Imai, Masaki Fukunaga, Hiroki Yamamoto, Yinghua Yu, Kazuhiko Seki, Takashi Hanakawa, Tatsuya Umeda, Jiajia Yang

Abstract read
In one paragraph

Article in NMR in biomedicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Chenyu WangGraduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama, Japan.
Hirohiko ImaiInnovation Research Center for Quantum Medicine, Gifu University School of Medicine, Gifu, Japan.
Masaki FukunagaSection of Brain Function Information, National Institute for Physiological Sciences, Okazaki, Japan.
Hiroki YamamotoGraduate School of Human and Environmental Studies, Kyoto University, Kyoto, Japan.
Yinghua YuGraduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama, Japan.
Kazuhiko SekiDepartment of Neurophysiology, National Center of Neurology and Psychiatry, Kodaira, Tokyo, Japan.
Takashi HanakawaDepartment of Integrated Neuroanatomy and Neuroimaging, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Tatsuya UmedaDepartment of Integrated Neuroanatomy and Neuroimaging, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Jiajia YangGraduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama, Japan.

Funding

Japan Agency for Medical Research and Development 100200600008Japan Agency for Medical Research and Development 22gm651002h0002Japan Agency for Medical Research and Development 24wm0625001h0002Japan Agency for Medical Research and Development 24wm0625217h0001Japan Science and Technology Agency JPMJFR2041
6 · The paper itself

Abstract

Common marmosets (Callithrix jacchus), small-bodied New World primates that share similar sensory processing pathways with human beings, have gained great interests. Their small body size allows imaging of brain activity with high spatial resolution and on a whole-brain scale using ultrahigh-field (UHF) magnetic resonance imaging (MRI) scanners. However, the strong magnetic field and the small size of the hand and forearm pose challenges in delivering tactile stimulation during fMRI experiments. In the present study, we developed an MR-compatible tactile dual-point stimulator to provide high-precision mechanical stimulation for exploring somatosensory processing in small-bodied animals. The study population consisted of a water phantom and three male common marmosets. Cerebral blood volume (CBV) weighted fMRI data were obtained with a gradient echo (GE), echo-planar imaging (EPI) sequence at 7T scanner. The output performance of the device was tested by a pressure sensor. The MR compatibility of the device was verified by measuring the temporal signal-to-noise ratio (tSNR) of a water phantom. To test the effectiveness of tactile stimulation, we conducted block designed tactile stimulation experiments on marmosets. A one-way repeated measures ANOVA was conducted for comparing the tSNR results. We performed one-sample t-tests to investigate the negative response of the forearm and hand stimulation with a threshold of t > 1.96 (p < 0.05). Performance tests revealed that mechanical stimulation (averaged force: 31.69 g) was applied with a delay of 12 ms. Phantom experiments confirmed that there was no significant difference in the tSNR among three (10 Hz, 1 Hz, and no-stimulus) conditions (F (2, 798) = 0.71, p = 0.49). The CBV activity results showed that the stimulator successfully elicited hand and forearm somatosensory activations in primary somatosensory areas. These results indicated that the device is well suited for small-bodied animal somatosensory studies.

Indexed as

CallithrixMagnetic Resonance ImagingPhysical StimulationSomatosensory CortexTouchAnimalsEquipment DesignMalePhantoms, ImagingSignal-To-Noise Ratioprimary somatosensory cortexsmall‐bodied animalstactile stimulation deviceultrahigh‐field magnetic resonance imaging

Identifiers

PMID40703000
PMCPMC12287889

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.