Evidence map›Paper›PMID 40702570›Full record

ArticleBiomedical engineering online2025

A hybrid model for detecting motion artifacts in ballistocardiogram signals.

Yuelong Jiang, Han Zhang, Qizheng Zeng

Abstract read
In one paragraph

Article in Biomedical engineering online, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yuelong JiangSchool of Electronics Science & Engineering (School of Microelectronics), South China Normal University, Foshan, 528200, China.
Han ZhangSchool of Electronics Science & Engineering (School of Microelectronics), South China Normal University, Foshan, 528200, China. zhanghan@scnu.edu.cn.
Qizheng ZengSchool of Electronics Science & Engineering (School of Microelectronics), South China Normal University, Foshan, 528200, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe field of contactless health monitoring has witnessed significant advancements with the advent of piezoelectric sensing technology, which enables the monitoring of vital signs such as heart rate and respiration without requiring direct contact with the subject. This is especially advantageous for home sleep monitoring, where traditional wearable devices may be intrusive. However, the acquisition of piezoelectric signals is often impeded by motion artifacts, which are distortions caused by the subject of movements and can obscure the underlying physiological signals. These artifacts can significantly impair the reliability of signal analysis, necessitating effective identification and mitigation strategies. Various methods, including filtering techniques and machine learning approaches, have been employed to address this issue, but the challenge persists due to the complexity and variability of motion artifacts.

methodsThis study introduces a hybrid model for detecting motion artifacts in ballistocardiogram (BCG) signals, utilizing a dual-channel approach. The first channel uses a deep learning model, specifically a temporal Bidirectional Gated Recurrent Unit combined with a Fully Convolutional Network (BiGRU-FCN), to identify motion artifacts. The second channel employs multi-scale standard deviation empirical thresholds to detect motion. The model was designed to address the randomness and complexity of motion artifacts by integrating deep learning capabilities with manual feature judgment. The data used for this study were collected from patients with sleep apnea using piezoelectric sensors, and the model's performance was evaluated using a set of predefined metrics.

resultsThis paper proposes and confirms through analysis that the proposed hybrid model exhibits exceptional accuracy in detecting motion artifacts in ballistocardiogram (BCG) signals. Employing a dual-channel approach, the model integrates multi-scale feature judgment with a BiGRU-FCN deep learning model. It achieved a classification accuracy of 98.61% and incurred only a 4.61% loss of valid signals in non-motion intervals. When tested on data from ten patients with sleep apnea, the model demonstrated robust performance, highlighting its potential for practical use in home sleep monitoring.

conclusionThe proposed hybrid model presents a significant advancement in the detection of motion artifacts in BCG signals. Compared to existing methods such as the Alivar method [29], Enayati method [22], and Wiard method [20], our hybrid model achieves higher classification accuracy (98.61%) and lower valid signal loss ratio (4.61%). This demonstrates the effectiveness of integrating multi-scale standard deviation empirical thresholds with a deep learning model in enhancing the accuracy and robustness of motion artifact detection. This approach is particularly effective for home sleep monitoring, where motion artifacts can significantly impact the reliability of health monitoring data. The study findings suggest that the proposed hybrid model could serve as a valuable tool for improving the accuracy of motion artifact detection in various health monitoring applications.

Indexed as

ArtifactsBallistocardiographyMotionSignal Processing, Computer-AssistedDeep LearningHumansMovementHybrid modelMotion artifact detectionPiezoelectric sensingSleep monitoring

Identifiers

PMID40702570
PMCPMC12288294

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.