Evidence map›Paper›PMID 40698855›Full record

ArticleJournal of synchrotron radiation2025

The 10 m collimated Rowland spectrometer at the MAX IV Veritas beamline.

Marcus Agåker, Carl Johan Englund, Victor Ekholm, Ludvig Kjellsson, Peter Sjöblom, Louisa Pickworth, Johan Söderström, Niklas Johansson, Anirudha Ghosh, Takashi Tokushima and 8 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

Marcus AgåkerMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.
Carl Johan EnglundDepartment of Physics and Astronomy, Uppsala University, PO Box 516, SE-75120 Uppsala, Sweden.
Victor EkholmMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.ORCID 0000-0002-3797-3346
Ludvig KjellssonMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.ORCID 0000-0001-9545-3579
Peter SjöblomMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.ORCID 0000-0001-6164-4908
Louisa PickworthMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.ORCID 0000-0002-0585-1934
Johan SöderströmDepartment of Physics and Astronomy, Uppsala University, PO Box 516, SE-75120 Uppsala, Sweden.ORCID 0000-0002-9647-0394
Niklas JohanssonDepartment of Physics and Astronomy, Uppsala University, PO Box 516, SE-75120 Uppsala, Sweden.
Anirudha GhoshMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.
Takashi TokushimaMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.ORCID 0000-0003-2586-0712
Marco CaputoMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.
Johan ForsbergMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.
Gábor FelcsutiMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.
Pierre FredrikssonDepartment of Physics and Astronomy, Uppsala University, PO Box 516, SE-75120 Uppsala, Sweden.
Suleyman MalkiMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.
Nial WassdahlMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.
Conny SåtheMAX IV Laboratory, Lund University, PO Box 118, SE-22100 Lund, Sweden.
Jan Erik RubenssonDepartment of Physics and Astronomy, Uppsala University, PO Box 516, SE-75120 Uppsala, Sweden.ORCID 0000-0003-1467-8114

Funding

Stiftelsen för Strategisk Forskning RIF14-0064
6 · The paper itself

Abstract

A grazing-incidence Rowland spectrometer with a collimating element for resonant inelastic soft X-ray scattering at the Veritas beamline at MAX IV, Lund, Sweden, is presented. The instrument is designed to operate in the 250-950 eV range, providing >30000 resolving power in first order. The inherent temporal resolution of the delay-line detector enables time-resolved experiments on the 270 ps time-scale and also allows for so-called time-gating which significantly improves the signal-to-noise ratio. The instrument is able to rotate around the sample position in the horizontal plane, which enables measurements of the momentum transfer in the X-ray scattering event. The instrument is prepared for installation of a polarimeter to provide full characterization of energy, momentum and polarization of the scattered photons. The design is evaluated using spectral measurements, ray-tracing, vibration and motion measurements.

Indexed as

instrumentRIXSsoft X-raysspectrometersynchrotron

Identifiers

PMID40698855
PMCPMC12416412

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.