Evidence map›Paper›PMID 40698363›Full record

ArticleFrontiers in bioengineering and biotechnology2025

Biomechanical evaluation of percutaneous cement discoplasty combined with percutaneous vertebroplasty: a finite element analysis.

Xu Zhou, Shenghua Qin, Chunhai Huang, Feiwen Li, Jin Liu, Ti Wu, Mingzheng Zhang

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xu Zhou *Department of Orthopaedics, The First Affiliated Hospital of Jishou University, Jishou University, Jishou, China.
Shenghua Qin *Department of Orthopaedics, The First Affiliated Hospital of Jishou University, Jishou University, Jishou, China.
Chunhai HuangDepartment of Orthopaedics, The First Affiliated Hospital of Jishou University, Jishou University, Jishou, China.
Feiwen LiDepartment of Orthopaedics, The First Affiliated Hospital of Jishou University, Jishou University, Jishou, China.
Jin LiuSchool of Medicine, Jishou University, Jishou, China.
Ti WuSchool of Medicine, Jishou University, Jishou, China.
Mingzheng ZhangSchool of Medicine, Jishou University, Jishou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Since the introduction of percutaneous cement discoplasty (PCD), numerous studies have confirmed its clinical efficacy in elderly patients. However, PCD is also associated with risks such as bone cement leakage and vertebral fractures. The purpose of this study was to present a biomechanical evaluation of two modified versions of PCD performed in combination with percutaneous vertebroplasty (PVP). Methods: Data from a CT scan of a healthy male's lumbosacral region were used to establish finite element (FE) models of nonsurgical treatment, PCD, L4/5PCD + L4L5PVP (modified technique 1, where the bone cement in the L4/5 disc space does not connect with the L4 and L5 vertebrae) and PCIF (modified technique 2, where the bone cement in the L4/5 disc space connects with the L4 and L5 vertebrae). A compressive of preload 150 N and a moment of 10 N·m were applied to recreate flexion, extension, lateral bending, and axial rotation. The range of motion (ROM) of L3/4 and L4/5, maximum stress on the L3 inferior endplate, L4 inferior endplate and L5 superior endplate, stress on the annulus fibrosus of L4/5, and displacement of the bone cement were evaluated. Results: Both modified techniques outperformed the simple PCD technique in reducing stress on the endplate, stress on the annulus fibrosus, and displacement of the bone cement. The L4/5PCD + L4L5PVP technique was more advantageous in terms of reducing the incidence of postoperative complications. The addition of the PVP technique significantly enhanced spinal stability by increasing support to adjacent vertebrae, thereby reducing the risk of postoperative endplate fractures and bone cement leakage. Conclusion: Modified PCD combined with PVP may be a safer and more effective option for treating degenerative disc diseases, providing important references for clinical treatment.

Indexed as

biomechanicsfinite element analysispercutaneous cement discoplastypercutaneous vertebroplastyspinal degeneration

Identifiers

PMID40698363
PMCPMC12279793