Evidence map›Paper›PMID 40697811›Full record

ArticleOrthopaedic journal of sports medicine2025

Rotator Cuff Repair Augmentation by Direct Interlocking of an Overlayed Nonwoven Polyethylene Terephthalate Patch Substantially Increases Repair Strength: A Biomechanical Comparison in Ovine Shoulders.

Bettina Hochreiter, Ronja Senn, Elias Bachmann, Jess G Snedeker, Karl Wieser

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bettina HochreiterDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
Ronja SennInstitute for Biomechanics, ETH Zurich, Zurich, Switzerland.
Elias BachmannZuriMED Technologies AG, Zurich, Switzerland.
Jess G SnedekerDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
Karl WieserDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Despite advancements in surgical treatment of rotator cuff tears, such as the implementation of patches to reinforce repairs, the rate of retears remains high. Construct failure often occurs at the suture-tendon interface. Purpose/Hypothesis: The purpose of this study was to compare the biomechanical properties of 3 types of rotator cuff repair (RCR): a nonaugmented transosseous-equivalent (TOE) repair, a conventional patch-augmented TOE repair, and a TOE repair augmented with a polyethylene terephthalate (PET) patch that directly interlocks with the underlying tendon across its entire interface. It was hypothesized that interlocked patch augmentation of RCR is biomechanically superior to conventional TOE. Study Design: Controlled laboratory study. Methods: A total of 18 ovine infraspinatus tendons were detached, repaired (with TOE), and tested in 3 groups (n = 6): (1) nonaugmented TOE, (2) conventional patch-augmented TOE, and (3) interlocked patch-augmented TOE. In the second group, a commercial synthetic polyester patch was attached to the tendon via No. 2 FiberWire sutures and laterally attached to the humerus using No. 2 FiberWire sutures and 2 knotless anchors. In the third group, an interwoven patch-tendon interface was created using a microblade to push the fibers of the patch directly into the underlying tissue and to the humerus as described above. Each specimen underwent cyclic loading, followed by pull-to-failure testing. Ultimate tensile strength, cyclic and linear stiffness, peak-to-peak elongation, and gap formation were measured. Results: Direct patch interlocking resulted in significantly higher tendon purchase during pull to failure (587 ± 109 N vs 222 ± 48 N and 211 ± 52 N) as well as cyclic stiffness testing (44 ± 3 N/mm vs 25 ± 2 N/mm and 29 ± 2 N/mm) compared with the conventional patch-augmented and nonaugmented TOE, respectively ( Conclusion: While limiting but not eliminating tendon retraction, augmentation of a conventional TOE with direct interlocking of a nonwoven PET patch provided biomechanically superior results compared with conventionally augmented and nonaugmented TOE RCRs. The interlocked patch not only significantly improved time-zero force to failure but, compared with a conventional commercial patch design, also increased linear stiffness. Clinical Relevance: Higher construct stiffness suggests that micromotion and gap formation were minimized, an aspect that is crucial for tendon-bone healing and for reducing early tendon retraction, thereby offering potential to improve retear rates in future clinical applications.

Indexed as

biomechanicsex vivo ovine modelpatch augmentationrotator cuff repair

Identifiers

PMID40697811
PMCPMC12280532

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.