ArticleInternational ophthalmology2025
The association of corneal thickness with ocular structures from corneal epithelium to optic nerve sheath diameter.
Article in International ophthalmology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo determine the association of central corneal thickness with corneal epithelium, ocular A-scan parameters, anterior chamber angle, and optic nerve sheath diameter.
methodsA total of 161 individuals with thick, thin or normal corneas, with average ages of 53.3, 56.8 and 52.9 years, respectively, were included in this study. During routine eye examination, the right and left eyes of those with corneas thicker than 600 µm or thinner than 500 µm were assessed by comparing them separately with the eyes of those with normal corneas and with each other. After the participants' corneal thicknesses were measured by a non-contact tonometry/pachymetry, anatomical structures such as anterior chamber depth, lens thickness, and axial length were calculated with the A-Scan mode of an ultrasound device, and optic nerve sheath diameter was measured by the B-Scan mode of the same analyzer. Measurements of anterior segment structures, including corneal epithelium, corneal pachymetry and anterior chamber angle were recorded with a spectral domain optical coherence tomography. The optic disc area was automatically measured with the same device and compared with the optic nerve sheath diameter and central corneal thickness.
resultsCentral corneal thickness was inversely correlated with age. Thicker central cornea was associated with smaller anterior chamber angle (for normal vs. thick 34.7 ± 5.7° and 29.4 ± 6.9°, P = 0.00, for normal vs. thin 34.7 ± 5.7° and 30.7 ± 7.3°, P = 0.00), whereas ocular A-scan parameters, including anterior chamber depth, lens thickness, and axial length did not show significant differences. Intraocular pressure measurements lower than 17.9 mmHg were significantly different between the groups, with the highest measurements obtained from the thick group (17.9 ± 3.2 mmHg, 15.3 ± 2.3 mmHg, and 16.7 ± 2.1 mmHg for thick, thin and normal corneas, respectively). Despite within normal limits in all groups, the optic nerve sheath diameter in the control group was significantly smaller than that in the thick and thin groups (4.23 ± 0.71 mm vs. 4.66 ± 0.54 mm for normal and thick, P = 0.00, 4.23 ± 0.71 mm vs. 4.58 ± 0.55 mm for normal and thin, P = 0.02). The epithelium at nine points in the thick corneas, was significantly thicker than the corresponding points of the other two groups (the central thickness of epithelium for the thick and thin 58.4 ± 3.9 µm vs. 52.8 ± 2.9 µm, P = 0.00, for the thick and normal 58.4 ± 3.9 µm vs. 53.4 ± 2.4 µm, P = 0.00). For the thick cornea group, optic nerve sheath diameter was significantly correlated with optic disc area (r = 0.86, P = 0.000) and central corneal thickness (P = 0.003, regression coefficients).
conclusionsThicker central cornea was associated with thicker corneal epithelium, smaller anterior chamber angle, greater optic nerve sheath diameter, and higher intraocular pressure readings.
Indexed as
Identifiers
40694268What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.