Evidence map›Paper›PMID 40693435›Full record

ArticleOrthopaedic surgery2025

Design of a Novel Artificial Atlanto-Odontoid Joint and Its Anatomical and Radiological Studies Following Transoral Pharyngeal Approach Arthroplasty.

Shengguang Lei, Lingyong Jing, Xijiong Chen, Zhiwei Gan, Jianbin Zhong, Liming Yu, Yong Hu

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shengguang LeiHealth Science Center, Ningbo University, Ningbo, China.
Lingyong JingDepartment of Orthopedic Trauma, Zhedong Orthopedic Hospital, Ningbo, China.
Xijiong ChenHealth Science Center, Ningbo University, Ningbo, China.
Zhiwei GanHealth Science Center, Ningbo University, Ningbo, China.
Jianbin ZhongDepartment of Spine Surgery, Ningbo No. 6 Hospital, Ningbo, China.
Liming YuDepartment of Spine Surgery, Ningbo Ninth Hospital, Ningbo, China.
Yong HuDepartment of Spine Surgery, Ningbo No. 6 Hospital, Ningbo, China.ORCID https://orcid.org/0000-0003-3393-2413

Funding

Major Special Project of Ningbo Municipal Bureau of Science and Technology 2023Z198
6 · The paper itself

Abstract

objectiveFor atlantoaxial joint disorders, traditional surgical approaches often presented challenges such as significant trauma and prolonged recovery. Therefore, it was crucial to explore safer and more effective surgical alternatives. The primary aim of this study was to investigate the anatomical safety and feasibility of artificial atlanto-odontoid joint (AAOJ) replacement via a transoral pharyngeal approach, through simulated surgical procedures and postoperative anatomical and radiological studies.

methodsThe novel AAOJ replacement surgery was simulated on 18 fresh adult cadaveric head and neck specimens, and relevant anatomical parameters were measured. Postoperatively, the specimens underwent X-ray and CT scans, and software was used to measure the relevant parameters of the fixation screws. The spatial relationships between the atlantoaxial components, fixation screws, and critical anatomical structures were also examined. The comparison of parameters between the left and right sides was conducted using paired-sample t-tests.

resultsThe transoral pharyngeal approach provided adequate exposure, clear surgical visualization, and sufficient working space. Anatomical measurements showed that the width of the anterior arch bone window of the atlas was (13.8 ± 0.7) mm; the width of the vertebral body bone window of the axis was (11.0 ± 0.4) mm; the distance between the insertion points for the atlas screws was (28.2 ± 4.0) mm; the distance from the atlas insertion points to the lateral joint edge of the atlanto-axial joint was (5.2 ± 0.9) mm; the distance between the insertion points for the axis screws was (16.8 ± 1.6) mm; and the distance from the axis insertion points to the lateral joint edge of the atlanto-axial joint was (7.7 ± 0.9) mm. Radiological measurements showed that the screw trajectory length of the lateral mass screw in the atlas was (21.5 ± 2.8) mm, the outward insertion angle was (13.2 ± 2.5)°, and the caudal insertion angle was (3.5 ± 1.1)°; for the pedicle screw of the axis, the screw trajectory length was (29.8 ± 2.8) mm, the outward insertion angle was (20.7 ± 2.8)°, and the caudal insertion angle was (16.6 ± 2.7)°. The prosthesis was precisely fitted to the upper cervical spine, with adequate safety distances between the atlantoaxial components, fixation screws, and critical anatomical structures such as the foramen transversarium, vertebral artery groove, and spinal canal.

conclusionsThe transoral pharyngeal approach for novel AAOJ replacement is anatomically safe and feasible.

Indexed as

Arthroplasty, ReplacementAtlanto-Axial JointJoint ProsthesisOdontoid ProcessProsthesis DesignAdultBone ScrewsCadaverFeasibility StudiesFemaleHumansMaleMiddle AgedPharynxTomography, X-Ray Computedarthroplastyartificial atlanto‐odontoid jointatlantoaxial instabilitytransoral pharyngeal approachupper cervical spine

Identifiers

PMID40693435
PMCPMC12404860

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.