Evidence map›Paper›PMID 40690179›Full record

ArticlePhysical and engineering sciences in medicine2025

Evaluation of volumetric modulated arc therapy dose calculation plans based on kV-cone beam CT images for the breast cancer treatment.

Amine El Outmani, M Zerfaoui, I Hattal, Y Oulhouq, K Bahhous, A Rrhioua, D Bakari, M Hamal, A Moussa

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Amine El OutmaniFaculty of Sciences, LPMR FSO Mohammed First University, 60000, Oujda, Morocco. am.eloutmani@ump.ac.ma.
M ZerfaouiFaculty of Sciences, LPMR FSO Mohammed First University, 60000, Oujda, Morocco.
I HattalFaculty of Sciences, LPMR FSO Mohammed First University, 60000, Oujda, Morocco.
Y OulhouqNational Institute for Research in Nuclear Physics and its Applications, Oujda, Morocco.
K BahhousFaculty of Medicine and Pharmacy, Mohammed First University, Oujda, Morocco.
A RrhiouaFaculty of Sciences, LPMR FSO Mohammed First University, 60000, Oujda, Morocco.
D BakariNational School of Applied Sciences, Mohammed First University, Oujda, Morocco.
M HamalFaculty of Sciences, LPMR FSO Mohammed First University, 60000, Oujda, Morocco.
A MoussaFaculty of Sciences, LPMR FSO Mohammed First University, 60000, Oujda, Morocco.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The majority of treatment centers currently use Cone Beam Computed Tomography (CBCT) as an effective method of patient repositioning, opening up the prospect of using it in treatment plans calculation. The purpose of this task is to investigate the feasibility of utilizing kV-CBCT images as a potential alternative to CT scans for generating treatment plans during radiation therapy. The images are taken by the imaging system installed on a linear accelerator and implemented in a Treatment Planning System (TPS). This imaging system opens the possibility to proceed to dose calculation using a calibration curve that establishes a link between voxel attenuation in Hounsfield Units (HU) and electron densities relative to water (RED). Furthermore, a comparison of Volumetric Modulated Arc Therapy (VMAT) treatment plans on this imaging modality was done to the Computed Tomography (CT) imaging system using the CIRS phantom. The comparison is also performed the images of 10 patients with right breast cancer. VMAT plans from the two modalities were compared in terms of target coverage, normal tissue sparing, dose distribution parameters, and monitor units (MUs). Then, the gamma index test is employed by using the PTW Verisoft to compare the TPS calculated dose distribution for the two modalities. It is also used to compare the measured dose distribution performed by the Portal Dosimetry. Regarding the volume-dose parameters of the PTV and the Organs at risk (OARs), no differences were found between the VMAT plans of the two imaging modalities, CT and CBCT. Additionally, the gamma analysis results of the patients VMAT plans for 1%-1 mm, 2%-2 mm, 3%-3 mm, 4%-4 mm and 5%-5 mm showed that more than 84%, 90%, 92%, 94%, and 96%, respectively, of the points agreed upon between Eclipse calculated and measured dose distributions for the CT and CBCT VMAT plans. The good dosimetric agreement (gamma index reaches more than 92% for 3%-3 mm) between breast VMAT plans based on CT and CBCT images renders the latter an appealing verification tool and a substitute for CT images, if needed, for dose calculation. CBCT images are an effective option for direct dose calculation or to do adaptive radiotherapy in the case of a breast cancer.

Indexed as

Breast NeoplasmsCone-Beam Computed TomographyRadiation DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedFemaleHumansPhantoms, ImagingRadiotherapy DosageBreast cancerDose calculationkV-CBCTTPSVMAT

Identifiers

PMID40690179

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.