ArticleJournal of robotic surgery2025
Comparison of traditional and robotic size prediction methods and stem positioning outcomes following prediction discrepancies in hip arthroplasty.
Article in Journal of robotic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study aims to evaluate the accuracy of prosthesis size prediction in MAKO robotic-assisted total hip arthroplasty (RATHA) and to assess the impact of discrepancies between the preoperative robotic plan and the actual sizes of femoral prostheses applied during surgery on the postoperative stem position. We conducted a retrospective analysis of preoperative planning, intraoperative records, and postoperative imaging data from patients who underwent RATHA. We predicted prosthesis sizes using both traditional 2D methods and robotic systems, comparing their accuracy. The cases were categorized into four groups based on the consistency between the robotic planned and applied femoral sizes: matched group, reduced group, enlarged group, and deviated group. The postoperative measurements of stem position were compared across these groups. The prediction accuracy of the robotic system for the acetabular cup (90.3% vs. 69.7%, P < 0.01) and femoral stem (75.7% vs. 59.5%, P < 0.01) was significantly higher than that of the traditional 2-D method. The absolute values of coronal plane angulation (CA) varied significantly among the three groups: 0.55° (0.15°-1.08°) in the enlarged group, 1.25° (0.40°-2.40°) in the matched group, and 2.55° (1.45°-3.13°) in the reduced group (P < 0.001). The safe zone ratio was higher in the enlarged (100%, P < 0.01) and matched groups (83.6%, P < 0.01) compared to the reduced group (60.7%). A larger stem was associated with a higher canal fill ratio (CFR) in planes C (P = 0.02) and D (P < 0.01). All data from the deviated group differed significantly from those of the other three groups. The robotic system provides a more accurate prediction of prosthesis size compared to traditional methods. The use of a smaller stem than planned was linked to a larger absolute CA and a smaller CFR. Conversely, applying a larger stem facilitates a more neutral stem position and improved press fitting. If the applied size is reduced by two or more compared to the postoperative plan, poor positioning of the femoral prosthesis should be suspected.