ArticleCureus2025
A Challenging Case of Endoscopic Retrograde Cholangiopancreatography Due to an Intradiverticular Papilla.
Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Periampullary diverticulum (PAD) is often encountered and associated with increased technical complexity and risk of procedural failure, particularly when the papilla is located within the diverticular lumen. We report a case of a 52-year-old male patient with biliary leakage secondary to metastatic colorectal carcinoma, in whom standard ERCP attempts failed due to the papilla's position within PAD. Given the challenging anatomy, endoscopic ultrasonography (EUS) was employed to evaluate biliary anatomy and facilitate guided access. Utilizing a cautery-enhanced lumen-apposing metal stent (LAMS), a successful EUS-guided choledochoduodenostomy was performed under fluoroscopic guidance, resulting in adequate biliary drainage without complications. A follow-up at two weeks demonstrated clinical improvement (normalizing bilirubin levels) and resolution of the biliary leakage. This case illustrates the potential utility of EUS-guided lumen-apposing stent placement, specifically the Hot-Axios, as a minimally invasive alternative in difficult biliary interventions involving PAD, with implications for reducing procedural time and improving success rates in anatomically complex scenarios.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.