Evidence map›Paper›PMID 40688339›Full record

ArticleJournal of thoracic disease2025

Safety and feasibility of performing rigid bronchoscopy in the bronchoscopy suite instead of the operating room.

Amit K Mahajan, Madelyn Bean, Mary Luu, Nancy Collar, Nihar Shah, Duy K Duong, Priya P Patel, Manjula Parne

Abstract read
In one paragraph

Article in Journal of thoracic disease, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Amit K MahajanSection of Interventional Pulmonology, Department of Surgery, Inova Fairfax Medical Center, Falls Church, VA, USA.
Madelyn BeanSection of Interventional Pulmonology, Department of Surgery, Inova Fairfax Medical Center, Falls Church, VA, USA.
Mary LuuSection of Interventional Pulmonology, Department of Surgery, Inova Fairfax Medical Center, Falls Church, VA, USA.
Nancy CollarSection of Interventional Pulmonology, Department of Surgery, Inova Fairfax Medical Center, Falls Church, VA, USA.
Nihar ShahSection of Interventional Pulmonology, Department of Surgery, Inova Fairfax Medical Center, Falls Church, VA, USA.
Duy K DuongSection of Interventional Pulmonology, Department of Surgery, Inova Fairfax Medical Center, Falls Church, VA, USA.
Priya P PatelSection of Interventional Pulmonology, Department of Surgery, Inova Fairfax Medical Center, Falls Church, VA, USA.
Manjula ParneSection of Interventional Pulmonology, Department of Surgery, Inova Fairfax Medical Center, Falls Church, VA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Rigid bronchoscopy is an invasive procedure used for the management of complex airway diseases. Complications related to rigid bronchoscopy are uncommon in the hands of trained physicians. Traditionally, rigid bronchoscopy is performed in the operating room rather than the bronchoscopy suite based on the availability of advanced airway equipment and additional anesthesia support. This study assesses the safety and feasibility of performing rigid bronchoscopy on non-critically ill patients in the bronchoscopy suite. The aim of this study is to determine the safety of performing rigid bronchoscopy in a bronchoscopy suite, outside of an operating room setting. Methods: This is a retrospective, single-center analysis of 372 rigid bronchoscopy procedures performed for complex airway interventions in the bronchoscopy suite over a 5-year period. The primary endpoint of this study was the safety of performing rigid bronchoscopy in the bronchoscopy suite. In this analysis, safety data was collected regarding intraoperative and post-operative complications of rigid bronchoscopies performed in the bronchoscopy suite. Results: Over a 5-year period between January 2019 and March 2024, 372 rigid bronchoscopies were performed in the bronchoscopy suite for non-emergent complex airway diseases. The overall incidence of intraprocedural complications in our cohort was 2 out of 372 procedures (0.5%). The two intraprocedural complications were pulmonary hemorrhage in 1 patient and cardiac ischemia in 1 patient. No incidence of airway injury, cardiac arrest, or death were observed. Seven procedures (1.9%) were followed by a change in clinical status requiring increased respiratory support within 24 hours of the rigid bronchoscopy. Conclusions: Rigid bronchoscopy for the treatment of complex airway diseases, in the appropriate patient population, can be performed safely in the bronchoscopy suite.