ArticlePhysics and imaging in radiation oncology2025

In-vitro effects of modern radiotherapy regimes on cardiac implanted electrical devices.

Steven Manley, Amy Fenwick, Megan Fraser, Mark Lowrey, Anna Walaszczyk, Nick West

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Steven ManleyDepartment of Medical Physics, The James Cook University Hospital, Middlesbrough TS4 3BW, UK.
Amy FenwickDepartment of Cardiac Rhythm Management, Freeman Hospital, Freeman Road, Newcastle upon Tyne NE7 7DN, UK.
Megan FraserDepartment of Cardiac Rhythm Management, Freeman Hospital, Freeman Road, Newcastle upon Tyne NE7 7DN, UK.
Mark LowreyDepartment of Cardiac Rhythm Management, Freeman Hospital, Freeman Road, Newcastle upon Tyne NE7 7DN, UK.
Anna WalaszczykDepartment of Cardiac Rhythm Management, Freeman Hospital, Freeman Road, Newcastle upon Tyne NE7 7DN, UK.
Nick WestNorthern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, NE7 7DN, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: External Beam Radiotherapy (EBRT) of patients with Cardiac Implanted Electrical Devices (CIEDs) have guidelines developed over many decades, during which both technologies have advanced. Consequently, guidelines may not reflect modern device interactions. Asynchronous modes, with pace sensing and shocks turned off whilst regulating pacing output, is used routinely for MRI scanning and could reduce risks for pace sensing errors in radiotherapy. Evidence is limited on modern radiotherapy using high dose, high doserate beams, with CIEDs in asynchronous mode. We present the effects of irradiating modern CIEDs using contemporary radiotherapy regimes. Materials and methods: One hundred and sixty explanted CIEDs were irradiated, to corroborate historical findings for modern devices in normal operational modes, and explore effects when in asynchronous mode. Regimes knowingly detrimental to CIEDs; 48 Gy single fraction, neutron producing, alongside clinically relevant regimes of 60 Gy in 5 fractions using 10 MV flattening filter free [FFF] beams at clinical, and maximal dose rates. Results: No significant changes occurred to pacing voltages from 60 Gy in 5 fractions 10 MV FFF deliveries in asynchronous mode.No evidence supported restricting 6 MV flattened beams for CIED patients, including defibrillation capable devices. Conclusions: This study demonstrates asynchronous mode can reduce the frequency of CIED malfunctions during EBRT. However, clinical context, risks and benefit must be evaluated per patient. While some current guidelines potentially compromise plan quality to reduce dose to the CIED, the use of asynchronous mode may provide planning options, which more closely align to non-CIED cases.

Indexed as

CIEDFFFHigh dose ratePacemakerRadiotherapySABR

Identifiers

PMID40687307
PMCPMC12271075