Evidence map›Paper›PMID 40687194›Full record

ArticleThe journal of advanced prosthodontics2025

Effects of scan body material, length and top design on digital implant impression accuracy and usability: an

Julian Hessel Baranowski, Victoria Franke Stenport, Michael Braian, Ann Wennerberg

Abstract read
In one paragraph

Article in The journal of advanced prosthodontics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Julian Hessel BaranowskiDepartment of Prosthodontics/Dental Materials Science, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.ORCID https://orcid.org/0009-0007-8571-2830
Victoria Franke StenportDepartment of Prosthodontics/Dental Materials Science, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.ORCID https://orcid.org/0000-0001-5911-3665
Michael BraianSwedish Organisation for Computer Aided Digital Dentistry, SWECADD, Malmö, Sweden.ORCID https://orcid.org/0000-0002-9128-9182
Ann WennerbergDepartment of Prosthodontics/Dental Materials Science, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.ORCID https://orcid.org/0000-0003-2957-1133

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study evaluated how implant scan body (ISB) design affects trueness and operator convenience of digital implant impressions. The null hypothesis stated no significant differences in trueness or usability between ISB designs. MATERIALS AND

methodsA cast metal model with nine implants and silicone mucosal masks (1 mm and 3 mm thickness) were used. Seven ISB prototypes were developed by modifying a commercial ISB (ELOS Accurate IO2A-B, ELOS Medtech) in four aspects: length (30% shorter and 50% longer), material (polyetheretherketone (PEEK) or titanium), surface reflectance (polished or aluminium oxide-blasted titanium), and top surface (concave top and screw holes enlarged by 100% and 200%). Each prototype was scanned ten times using an intraoral scanner (NeoScan1000, Neoss), with a desktop scanner (E3, 3Shape) providing reference scans. Deviations in depth, angulation, and rotation were analyzed in CAD software (GOM Inspect, Zeiss). Statistical analysis included the Welch test (

resultsMaterial affected depth accuracy; blasted titanium (89 ± 86 µm) and polished titanium (80 ± 72 µm) outperformed PEEK (149 ± 131 µm). Shorter ISBs showed greater angular deviations (0.64 ± 0.70°) compared to control (0.31 ± 0.21°). Rotational deviations were not significant. Scanning times increased for reflective, longer ISBs with reduced top areas, while shorter ISBs improved usability.

conclusionISB design influences digital impression accuracy. Titanium ISBs with reduced reflectivity improve trueness, and larger screw holes enhance usability. Shorter ISBs reduce scanning time but compromise angular trueness. Stitching errors remain the primary source of depth inaccuracies.

Indexed as

Computer-aided designDental implantDental impression techniquesDental prosthesis, Implant supportedImagingThree-dimensional

Identifiers

PMID40687194
PMCPMC12270716

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.