Evidence map›Paper›PMID 40686660›Full record

ArticleArthroplasty today2025

Effects of the Flip Technique on Measurement Accuracy of the Acetabular Cup Position Using a Portable Hip Navigation System With Patients in the Lateral Decubitus Position.

Hiromasa Tanino, Ryo Mitsutake, Hiroshi Ito

Abstract read
In one paragraph

Article in Arthroplasty today, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hiromasa TaninoDepartment of Orthopaedic Surgery, Asahikawa Medical University, Asahikawa city, Hokkaido, Japan.
Ryo MitsutakeDepartment of Orthopaedic Surgery, Asahikawa Medical University, Asahikawa city, Hokkaido, Japan.
Hiroshi ItoDepartment of Orthopaedic Surgery, Asahikawa Medical University, Asahikawa city, Hokkaido, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Accurate cup placement is performed for achieving satisfactory outcomes after total hip arthroplasty. Portable hip navigation systems are novel intraoperative tools for accurate cup placement. Several factors have been reported to affect their accuracy, including the flip technique, in which the pelvic reference plane is registered in the supine position and the patient is subsequently repositioned to the lateral decubitus position for surgery. The effectiveness of the flip technique remains a subject of debate. Therefore, this study assessed and compared the accuracy of cup position measurements using an inertial portable hip navigation system in the lateral decubitus position. Methods: Measurement accuracy was assessed in 78 hips. The accuracy of the system was compared with and without the flip technique, employing an identical method for registering the pelvic reference plane. Cup angles displayed on the system during surgery were compared with those measured postoperatively. Results: Measurement errors with and without the flip technique were 3.7° ± 2.8° and 2.8° ± 2.6° for cup abduction ( Conclusions: This system provided reliable intraoperative measurements of cup positions, irrespective of the use of the flip technique. However, cup abduction measurements were more accurate without the flip technique, while cup anteversion measurements were more accurate with the flip technique.

Indexed as

Cup positionFlip techniqueNavigationPortableTotal hip arthroplasty

Identifiers

PMID40686660
PMCPMC12273220

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.