Evidence map›Paper›PMID 40681547›Full record

ArticleScientific reports2025

Preferred screw placement area identified by imaging based quadrant and heatmap analysis for long screw fixation in Ogawa I coracoid process fractures.

Xiao Wang, Yang Wang, Haibo Xu, Zhaowei Yin, Dawei Ge, Bin Liang, Junwei Yan

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiao Wang *Department of Orthopaedics, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China.
Yang Wang *Department of Orthopaedics, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China.
Haibo XuDepartment of Orthopaedics, Nanjing Qixia District Hospital, 28 Yaojia Road, Nanjing, 210046, China.
Zhaowei YinDepartment of Orthopaedics, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China.
Dawei GeDepartment of Orthopaedics, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China.
Bin LiangDepartment of Orthopaedics, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China. liangbin80173@126.com.
Junwei YanDepartment of Orthopaedics, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China. yan_jw@yeah.net.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ogawa I coracoid process fractures are relatively rare. Surgical fixation requires precise determination of the screw length and direction to avoid iatrogenic injuries. Identifying the preferred screw placement area (PSPA) through imaging techniques is crucial for enhancing surgical safety and stability. This study utilized shoulder computed tomography (CT) data from 100 adult patients, employing three-dimensional (3D) modelling and simulated surgeries to analyze the PSPA for long screw fixation in Ogawa I coracoid process fractures. Scapular Y-view two-dimensional (2D) fluoroscopic images were divided into quadrants. Using scatter plots and heatmap techniques, we identified the PSPA, cautious screw placement area (CSPA), and danger screw placement area (DSPA). Preliminary validation was conducted through a cadaveric bone experiment and 9 clinical cases. The screw tip clusters were primarily distributed in the posterior-lower quadrant of the scapular Y-view images. The red and orange regions on the heatmap indicate the PSPA. The lengths of the longest (L1) and shortest screws (L2) were 53.44 ± 5.37 mm and 40.74 ± 6.02 mm, respectively. Male patients required longer screws, with significant sex differences (P < 0.05). Cadaveric bone experiments and in vivo validation demonstrated that screw placement via the PSPA effectively prevented screw perforation. This imaging study, employing the quadrant method, explored a potential PSPA for long screw fixation in Ogawa I coracoid process fractures. Initial observations from cadaveric and clinical settings suggest that this approach might assist in intraoperative screw orientation and could contribute to a reduced risk of iatrogenic injury.

Indexed as

Bone ScrewsCoracoid ProcessFracture Fixation, InternalFractures, BoneAdultAgedCadaverFemaleFluoroscopyHumansImaging, Three-DimensionalMaleMiddle AgedScapulaTomography, X-Ray ComputedYoung AdultCoracoid process fractureLong screw fixationOgawa classificationPreferred screw placement areaScapular Y-view imaging

Identifiers

PMID40681547
PMCPMC12274602

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.