ArticleInternational journal of surgery case reports2025
More than a mechanical problem: Dysphagia and new-onset ineffective esophageal motility after LINX® placement-a case report.
Article in International journal of surgery case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Cost-effectiveness of RefluxStop for gastroesophageal reflux disease: analysis from an Italian healthcare perspective.BMC gastroenterology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionMagnetic sphincter augmentation (MSA) with the LINX® device is an effective surgical option for gastroesophageal reflux disease (GERD), offering benefits such as preservation of belching and reduced gas bloat syndrome compared to Nissen fundoplication. However, postoperative dysphagia is common complication, occurring in approximately 15-30 % of patients. CASE PRESENTATION: We report the case of a 66-year-old female who underwent laparoscopic hiatal hernia repair with concurrent LINX® device placement for GERD. Three weeks postoperatively, she developed progressive dysphagia that was initially responsive to corticosteroids but recurred. Barium swallow demonstrated mild narrowing at the gastroesophageal junction. Despite three serial endoscopic dilations, her symptoms persisted. High-resolution manometry (HRM) revealed new-onset ineffective esophageal motility (IEM), in contrast to her preoperative study, which showed normal esophageal peristalsis. The LINX device was surgically removed due to refractory symptoms. Post-removal, the patient experienced significant symptomatic improvement. Repeat HRM one year later showed improved motility findings. DISCUSSION: This case illustrates the potential for MSA to contribute to the development of esophageal dysmotility in patients with subtle or predisposing motility abnormalities. Early postoperative dysphagia should prompt repeat manometric evaluation and consideration of device removal in refractory cases.
conclusionMSA may lead to de novo IEM. Thorough preoperative evaluation and timely reassessment of postoperative symptoms are key to optimizing patient outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.