Evidence map›Paper›PMID 40680046›Full record

ArticlePloS one2025

Repeatability of corneal curvature with the MS-39 anterior segment tomographer in a cataractous population.

Achim Langenbucher, Nóra Szentmáry, Alan Cayless, Muntadher Al Karam, Theo G Seiler, Jascha Wendelstein

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Achim LangenbucherDepartment of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany.ORCID https://orcid.org/0000-0001-9175-6177
Nóra SzentmáryDr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, Homburg/Saar, Germany.
Alan CaylessSchool of Physical Sciences, The Open University, Milton Keynes, United Kingdom.
Muntadher Al KaramInstitute for Refractive- and Ophthalmic Surgery (IROC), Zurich, Switzerland.
Theo G SeilerInstitute for Refractive- and Ophthalmic Surgery (IROC), Zurich, Switzerland.
Jascha WendelsteinDepartment of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to investigate the repeatability of optical coherence tomography in measuring radius of curvature (ROC) and asphericity (Q) of corneal epithelium, stroma and endothelium in a large patient cohort.

methodsIn this retrospective non-randomized cross sectional single-center study we evaluated a dataset containing 600 anterior segment optical coherence tomography measurements from 200 eyes (3 repeat measurements each) taken prior to cataract surgery. Measurements were exported containing height map data for the epithelium, stroma and endothelium surface. Model surfaces (floating sphere in a 3 (BFS3) and 6 mm zone (BFS6) and conic surface in a 3 (Conoid3) and 6 mm zone (Conoid6)) were fitted using nonlinear iterative optimization minimizing the height difference between measurement and model. The mean (MEAN) and standard deviations (SD) for each sequence of measurements were derived and analyzed.

resultsMEAN ROC for epithelium was 7.68/7.72/7.67/7.67 mm with BFS3/BFS6/Conoid3/Conoid6 and Q was -0.16/-0.19 with Conoid3/Conoid6. Corresponding values for stroma were 7.62/7.64/7.55/7.58 mm and -0.38/-0.24, and for endothelium they were 6.43/6.49/6.40/6.37 mm and -0.29/-0.33. Variations of the 3 repeat measurement ranged between 7-19/18-31/21-32 micron for epithelium/stroma/endothelium, and variation in Q was 0.14/0.20/0.14 with Conoid3 and 0.03/0.05/0.06 with Conoid6.

conclusionsFitting floating sphere or conoid model surfaces to the map data seems to be a very robust and reliable method for extracting ROC and asphericity from all data within a region of interest. For extraction of asphericity, the 6 mm zone should be used due to fewer variations.

Indexed as

CataractCorneaTomography, Optical CoherenceAgedAged, 80 and overCataract ExtractionCross-Sectional StudiesEpithelium, CornealFemaleHumansMaleMiddle AgedReproducibility of ResultsRetrospective Studies

Identifiers

PMID40680046
PMCPMC12273994

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.