Evidence map›Paper›PMID 40679329›Full record

ArticleTranslational vision science & technology2025

Intraoperative Spectrally Encoded Coherence Tomography and Reflectometry (iSECTR) for Ophthalmic Surgical Guidance.

Rachel Hecht, Jacob J Watson, Yuankai K Tao

Abstract read
In one paragraph

Article in Translational vision science & technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Rachel HechtDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
Jacob J WatsonDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
Yuankai K TaoDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.

Funding

Point-of-care ophthalmic diagnostic imaging of retinopathy of prematurityR01EY033969 · NEI · VANDERBILT UNIVERSITY · PI Ipek Oguz, Yuankai Kenny Tao · 2023 to 2026
$2.3M
Intraoperative Optical Coherence Tomography for Ophthalmic Surgical GuidanceR01EY030490 · NEI · VANDERBILT UNIVERSITY · PI TAO, YUANKAI KENNY · 2019 to 2023
$1.8M
Intraoperative imaging of macular hole repair to predict visual function outcomesR01EY031769 · NEI · VANDERBILT UNIVERSITY · PI TAO, YUANKAI KENNY · 2020 to 2023
$1.4M
NEI NIH HHS R01 EY030490NEI NIH HHS R01 EY031769NEI NIH HHS R01 EY033969
6 · The paper itself

Abstract

Purpose: We present an optimized intraoperative spectrally encoded coherence tomography and reflectometry (iSECTR) system integrated with a Zeiss OPMI VISU 200 ophthalmic surgical microscope (Zeiss, Oberkochen, Germany). Methods: An iSECTR scan-head was designed to overcome previous barriers to clinical translation by improving system stability, optimizing optical throughput, reducing reflection artifacts, and adding motorized focus-adjust functionality. The iSECTR imaging performance was demonstrated in in vivo human eyes and during simulated ophthalmic surgical maneuvers in ex vivo porcine eyes. Results: The optimized iSECTR scan-head achieved a footprint of 19.67 × 30.2 cm (width × length) and a surgical microscope stack height increase of only 6.06 cm. Motorized focusing was able to accommodate for ±10 D of focal shift to accommodate refractive power differences across surgeons. In vivo and ex vivo iSECTR imaging was able to resolve clinically relevant retinal and corneal tissue features and tissue deformation from conventional surgical instruments during simulated ophthalmic surgical maneuvers. Conclusions: This work demonstrates the performance of our iSECTR scan-head for ophthalmic intraoperative optical coherence tomography (iOCT). Our robust modular design allows for stable performance that is suitable for clinical translation. The improved spectrally encoded reflectometry (SER) imaging performance allowed for reproducible anterior and posterior eye imaging in both in vivo and ex vivo eyes, and independent iSECTR focus-adjust further enhances clinical ergonomics. Clinical translation of iSECTR technologies will provide a research platform for automated retinal- and instrument-tracking and four-dimensional visualization of surgical dynamics. Translational Relevance: Design considerations for minimizing footprint, microscope stack height, and integration of motorized focus-adjust were emphasized to benefit surgical ergonomics and clinical translation.

Indexed as

Ophthalmologic Surgical ProceduresSurgery, Computer-AssistedTomography, Optical CoherenceAnimalsHumansSwine

Identifiers

PMID40679329
PMCPMC12302043

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.