Evidence map›Paper›PMID 40679039›Full record

ArticleJournal of separation science2025

Flow Injection Inductively Coupled Plasma-Mass Spectrometry With Ultrasonic Nebulizer for the Quantification of Trace Elements in Seawater: An Innovative Method Targeting Cadmium, Cobalt, Lead, Manganese, Molybdenum, Tin, Uranium, and Vanadium.

Giorgia Mattei, Clara Sette, Luca Lucentini, Enrico Veschetti

Abstract read
In one paragraph

Article in Journal of separation science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Giorgia MatteiNational Centre for Water Safety, Italian National Institute of Health, Rome, Italy.
Clara SetteNational Centre for Water Safety, Italian National Institute of Health, Rome, Italy.
Luca LucentiniNational Centre for Water Safety, Italian National Institute of Health, Rome, Italy.
Enrico VeschettiNational Centre for Water Safety, Italian National Institute of Health, Rome, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The accurate determination of trace elements in seawater is essential for environmental monitoring and the study of oceanic biogeochemical processes. However, traditional analytical techniques often face limitations due to the ultra-trace concentrations of metals and the high salinity of seawater, which introduces significant matrix effects. In this study, a novel flow injection-inductively coupled plasma mass spectrometry (FI-ICP-MS) method coupled with an ultrasonic nebulizer was developed and optimized for the direct quantification of cadmium, cobalt, lead, manganese, molybdenum, tin, uranium, and vanadium in seawater samples. The method was optimized by evaluating the effects of eluent concentration (0.05-0.20% HNO3, with 0.05% selected as the minimum effective value to ensure analyte stability, prevent precipitation, and minimize salt-related stress on the FI system), flow rate (0.4-1.0 mL/min), and sodium chloride matrix composition, ensuring minimal spectral interferences while maintaining high sensitivity. The selected operating conditions (0.05% HNO3 eluent at 0.70 mL/min with 103Rhodium and 193Iridium as internal standards) provided a robust analytical performance with low procedural limits of detection and quantification (ranging from 0.003 to 0.2 µg/L for LoDs and from 0.01 to 0.7 µg/L for LoQs) and excellent instrumental repeatability (1.2%-6.6%). The overall method was validated using the IAEA-443 seawater certified reference material, yielding recoveries between 104%-118% and procedural reproducibility ranging from 3.8% to 15%. The optimized FI-ICP-MS method was applied to real seawater samples collected from two distinct Mediterranean transects: offshore Livorno, a site influenced by intense maritime and industrial activities, and Montecristo Island, a protected marine reserve with minimal anthropogenic impact. Results indicated no significant differences in trace metal concentrations between the two areas, suggesting that natural geochemical processes predominantly regulate elemental distributions. Most elements followed a conservative vertical distribution, with localized anomalies observed for manganese and cadmium. Furthermore, all measured cadmium and lead concentrations were well below the regulatory thresholds set by Directive 2013/39/EU, confirming compliance with environmental quality standards.

Indexed as

direct analysisflow injection ICP‐MSseawatertrace elements

Identifiers

PMID40679039
PMCPMC12272814

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.