ArticleHardwareX2025
Respiratory pressure and flow data collection device providing a framework for closed-loop mechanical ventilation.
Article in HardwareX, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This article details a pressure and flow sensor system device which enables a framework for the research and development of personalized mechanical ventilator support in a closed-loop or semi-closed-loop control system, where the measurements from this device could be hooked to digital twin models and any ventilator allowing open control. In current practice, patient response to mechanical ventilation is highly variable. Furthermore, current weaning best-practice relies on clinical experience which can lead to variability and inequality in both care and health outcomes. Personalized care can improve these inequalities in care due to patient variability when combined with digital twin models, which simulate physiology based on patient specific data, by improving the level of care possible in the ICU (Intensive Care Unit), regardless of clinician experience and/or patient variability. The device consists of two 3D printed custom Venturis and a Y-piece, with differential pressure sensors measuring gauge, inhalation, and exhalation pressure at the patient. The sensor system has an operating range of ±50.8 cmH
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.