Evidence map›Paper›PMID 40678014›Full record

ArticlePhysics and imaging in radiation oncology2025

Cone-beam CT-based estimations of prostate motion and dose distortion during radiotherapy.

Karolina A Klucznik, Thomas Ravkilde, Simon Skouboe, Ditte S Møller, Steffen Hokland, Paul Keall, Simon Buus, Lise Bentzen, Per R Poulsen

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Karolina A KlucznikDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
Thomas RavkildeDepartment of Oncology, Aarhus University Hospital, Aarhus, Denmark.
Simon SkouboeDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
Ditte S MøllerDepartment of Oncology, Aarhus University Hospital, Aarhus, Denmark.
Steffen HoklandDepartment of Oncology, Aarhus University Hospital, Aarhus, Denmark.
Paul KeallACRF Image X Institute, Sydney Medical School, University of Sydney, Australia.
Simon BuusDepartment of Oncology, Aarhus University Hospital, Aarhus, Denmark.
Lise BentzenDepartment of Oncology, Vejle Hospital, University of Southern Denmark, Vejle, Denmark.
Per R PoulsenDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Intra-fractional prostate translational and rotational (6DoF) motion can cause dose distortions. As intra-fractional motion monitoring is often unavailable, this study compares three methods to use pre- and post-treatment cone beam CTs (CBCT) to estimate prostate positioning errors during treatment and their dosimetric impact. Material and Methods: Eighteen patients received prostate radiotherapy with pre-treatment CBCT setup. For 7-10 fractions per patient (total:174), triggered kV-images were acquired every 3 s during beam-on and a CBCT was acquired post-treatment. The 6DoF prostate position error during treatment was determined from the kV-images (ground truth) and estimated from the CBCTs assuming a static position as in the pre-CBCT(Scenario1), a linear drift between pre- and post-CBCT position(Scenario2) or a static position as in the post-CBCT(Scenario3). The positioning errors and prostate dose from each scenario were compared with the ground truth. Results: Scenario1 was inferior to the others with prostate position root-mean-square errors of 1.1 mm(LR), 1.7 mm(AP) and 1.8 mm(CC). Scenario2 and 3 were similarly accurate with root-mean-square errors of 0.5 mm(LR), 0.9 mm(AP) and 0.8 mm(CC) (Scenario2) and 0.6 mm(LR), 1.1 mm(AP) and 0.9 mm(CC) (Scenario3). The prostate position errors reduced the CTV D Conclusion: Using the post-CBCT prostate position, acquired right after treatment, performed best in detecting intra-fractional prostate position errors and CTV dose deficits. It offers a scalable and conservative estimate of motion-induced dose distortions.

Indexed as

Cone Beam CTImage guided radiotherapyIntra-fractional motionProstate radiotherapy

Identifiers

PMID40678014
PMCPMC12269408

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.