Evidence map›Paper›PMID 40677488›Full record

ArticleCureus2025

Bedside Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Assessing Increased Intracranial Pressure: An Observational Study.

Saurav Shekhar, Raj B Singh, Preeti Sharma, Swapna Lata, Nitin Kumar, Ranjeet Rana De, Amit Kumar

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Saurav ShekharAnesthesiology (Trauma and Emergency), Indira Gandhi Institute of Medical Sciences, Patna, IND.
Raj B SinghAnesthesiology (Trauma and Emergency), Indira Gandhi Institute of Medical Sciences, Patna, IND.
Preeti SharmaOtolaryngology, Patna Medical College & Hospital, Patna, IND.
Swapna LataAnesthesia and Critical Care, Indira Gandhi Institute of Medical Sciences, Patna, IND.
Nitin KumarEmergency Medicine, Indira Gandhi Institute of Medical Sciences, Patna, IND.
Ranjeet Rana DeAnesthesiology (Trauma and Emergency), Indira Gandhi Institute of Medical Sciences, Patna, IND.
Amit KumarRadiology, Indira Gandhi Institute of Medical Sciences, Patna, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Traumatic brain injury (TBI) is a leading cause of disability and mortality, particularly in resource-limited settings where advanced neuromonitoring tools are often unavailable. Elevated intracranial pressure (ICP) is a serious and potentially life-threatening complication of TBI. Traditional methods for monitoring ICP are invasive, expensive, and require specialized expertise. Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) offers a noninvasive, real-time, and radiation-free alternative for assessing ICP. Objective This study aimed to evaluate the diagnostic accuracy of bedside ONSD measurement in detecting elevated ICP among neurotrauma patients, using CT imaging as the reference standard. Additionally, it explored the relationship between ONSD measurements, TBI severity, and neurological outcomes. Methods A prospective observational study was conducted on 100 adult patients with TBI, in whom bilateral ONSD measurements were obtained using a high-frequency linear ultrasound probe. Based on CT scan findings, patients were classified as having either raised or normal ICP. Statistical analyses included sensitivity, specificity, positive and negative predictive values, receiver operating characteristic curve analysis, and logistic regression to assess the diagnostic and prognostic utility of ONSD. Results Raised ICP was observed in 67% of patients, most of whom had moderate to severe TBI. ONSD values increased with injury severity: mild (4.53 ± 0.14 mm), moderate (5.24 ± 0.15 mm), and severe (5.90 ± 0.25 mm). A cutoff value of 5.2 mm demonstrated 95.5% sensitivity, 93.9% specificity, and an area under the curve of 0.96. An ONSD greater than 5.5 mm was strongly associated with poor neurological outcomes (Glasgow Outcome Scale scores 1-3), with an OR of 4.6 (p < 0.001). Conclusions Bedside ultrasonographic measurement of ONSD is a reliable and accurate method for detecting elevated ICP in TBI patients. It correlates strongly with both injury severity and clinical outcomes, making it a valuable tool in emergency and intensive care settings. Further studies comparing this technique with invasive monitoring methods and evaluating long-term outcomes are warranted.

Indexed as

glasgow coma scaleintracranial pressureneurological outcomeoptic nerve sheath diametertraumatic brain injuryultrasonography

Identifiers

PMID40677488
PMCPMC12266947

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.