ArticlePloS one2025
Accurate full-scale patient-specific Circle of Willis models including aneurysms: A novel manufacturing approach.
Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAccurate physical replicas of the Circle of Willis (CoW) are valuable for planning neuroendovascular interventions, validating computational simulations, evaluating medical devices and training physicians. Existing methods often replicate only segments of the CoW or lack geometric precision, which is critical for realistic hemodynamic simulations.
objectiveWe introduce a novel, cost-effective manufacturing approach to create full-scale, patient-specific CoW models using fused deposition modeling (FDM) 3D printing and lost core silicone casting. We aim to evaluate the accuracy and reproducibility of this manufacturing process.
methodsA patient-specific 3D model of the CoW with four saccular aneurysms was generated from time-of-flight magnetic resonance angiography (TOF-MRA) data. Three identical models were printed using FDM with acrylonitrile styrene acrylate (ASA) for the vascular structure and butenediol vinyl alcohol co-polymer (BVOH) as a water-soluble support material. The printed models were encased in a clear silicone block and the ASA core was then dissolved using acetone. Computed tomography (CT) scans were used to assess geometric accuracy through cloud-to-mesh distance calculations and centerline analysis.
resultsThe median absolute surface deviation between the replicas and the initial model was approximately 309 µm for the entire CoW, with interquartile ranges (IQR) between 360 µm and 444 µm. The aneurysm surfaces exhibited lower deviations, averaging 90 µm. Centerline analysis showed median absolute deviations in vessel radius ranging from 48 µm to 114 µm across key vascular pathways. Statistical analysis confirmed minimal discrepancies between replicas and the initial model. Each replica costs approximately €100 in materials and requires five days to produce.
conclusionThe manufacturing approach produces accurate, reproducible full-scale, patient-specific CoW models, including four aneurysms. This method simplifies the production process, reduces costs and maintains high geometric accuracy, making it suitable for hemodynamic studies, device evaluation, and clinical training.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.