Evidence map›Paper›PMID 40674110›Full record

ArticleEpilepsia2025

HD-EEG source imaging with simultaneous SEEG recording in drug-resistant epilepsy.

Shenglin Hao, Haifeng Zhao, Ziyi Feng, Wei Liu, Chao Zhang, Hang Ping, Qiang Zhou, Bomin Sun, Shikun Zhan, Chunyan Cao

Abstract read
In one paragraph

Article in Epilepsia, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Shenglin HaoNeurosurgical Department, Affiliated Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Haifeng ZhaoNeurosurgical Department, Affiliated Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Ziyi FengNeurosurgical Department, Affiliated Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Wei LiuNeurosurgical Department, Affiliated Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Chao ZhangNeurosurgical Department, Affiliated Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.ORCID https://orcid.org/0000-0002-1083-6587
Hang PingSchool of Electrical Engineering and Computer Science, Ningbo University, Ningbo, China.ORCID https://orcid.org/0009-0005-5842-0838
Qiang ZhouDepartment of Laboratory Medicine, Gongli Hospital, Shanghai, China.
Bomin SunNeurosurgical Department, Affiliated Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Shikun ZhanNeurosurgical Department, Affiliated Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Chunyan CaoNeurosurgical Department, Affiliated Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.ORCID https://orcid.org/0000-0002-3685-5700

Funding

National Natural Science Foundation of China 82071547
6 · The paper itself

Abstract

objectiveThis study aimed to assess the complementary role of high-density electroencephalography (HD-EEG)-based electrical source imaging (ESI) in localizing the seizure-onset zone (SOZ) during ictal events and the irritative zone (IZ) during the interictal period, using simultaneous acquired stereo-EEG (SEEG) recordings as a reference. In addition, we investigated the relationship of ictal cortical source activity with their scalp and intracranial EEG correlates, focusing on factors influencing ESI accuracy.

methodsWe enrolled 29 patients with drug-resistant epilepsy who underwent simultaneous HD-EEG and SEEG recordings. ESI was performed on ictal and interictal discharges of HD-EEG identified via SEEG, and localization accuracy was assessed relative to SEEG-defined sources. A linear mixed-effects model was applied to examine the influence of source depth and spike power on ESI accuracy. Concordance between ictal ESI and SEEG localizations was analyzed, along with associations with post-surgical outcomes.

resultsSynchronized rhythmic discharges, ranging from 1.95 to 8.77 Hz (mean 5.34 ± 2.14 Hz), but not the low-amplitude fast rhythms in SEEG were mandatory as references for ictal ESI. Ictal ESI periods (14.07 ± 4.62 mm) demonstrated significantly better localization accuracy than interictal ESI periods (17.38 ± 4.16 mm), with a shorter Euclidean distance between ESI dipoles and SEEG contacts. Both ictal spike power and source depth significantly influenced ESI accuracy. Patients with superficial or high-power discharges showed more precise localization. Concordant ictal ESI and SEEG results predicted favorable surgical outcomes (p = .006, n = 28). SIGNIFICANCE: Ictal ESI provides superior localization performance compared to interictal ESI. SEEG-informed analysis of ictal scalp EEG provides critical insights into SOZ characteristics, including location, depth, and spatial complexity. Simultaneous HD-EEG and SEEG recordings enhance the understanding of epileptogenic networks and support surgical decision-making in drug-resistant epilepsy.

Indexed as

Drug Resistant EpilepsyElectroencephalographyAdolescentAdultBrain MappingElectrocorticographyFemaleHumansMaleMiddle AgedYoung Adultelectrical source imagingictal and interictalsimultaneous EEG‐SEEG recordingsource localization accuracy

Identifiers

PMID40674110
PMCPMC12661267

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.